13.56 MHz Contactless
iCLASS SE® / multiCLASS SE®
R10E, RP10E, R15E, RP15E, R40E, RP40E, RK40E, RPK40E
R10MA, RP10MA, RP15MA, R40MA, RP40MA, RPK40MA
Parts
1 – iCLASS SE/multiCLASSS SE Reader
1 – Installation Guide
2 – #6-32 x .375” Phillips machine screws
3 – #6-32 x .375” spanner security screw
2 – 7-pin Terminal connectors
1 – 10-pin Terminal connector
Recommended
• Cable, 5-9 conductor (Wiegand or Clock-and-Data), 4 conductor Twisted
Pair Over-All Shield and UL approved, Belden3107A or equivalent (OSDP)
• Linear DC power supply
• Metal or plastic junction box
• Security tool (for anti-tamper screw) HID 04-0001-03
• Drill with various bits for mounting hardware
• Mounting hardware
• Reader spacer when mounting on or near metal or metal junction boxes -
see How to Order Guide
• IP65 Mounting gasket, recommended for outdoor installation
• Back box
Specification
PRODUCT
BASE PART
NUMBER
INPUT
VOLTAGE (VDC)
CURRENT
1
OPERATING
TEMPERATURE
5
CABLE LENGTH
6
REGULATORY
REF NUMBER
STANDBY
AVG
2
MAX
AVG
3
PEAK
4
R10
7
900N
5 - 16VDC
60mA
95mA
200mA
-30° to 150° F
(-35° to 65° C)
Communication Lines
Wiegand
= 500 ft - 22 AWG (152 m)
300 ft - 24 AWG 91 m)
RS-485
= Max bus length
4000 ft - 24 AWG (1,219 m)
Max length between nodes:
1640 ft - 24 AWG (500m)
R10Ex
1
x
2
x
3
RP10
7
900P
75mA
100mA
RP10Ex
1
x
2
x
3
900L
110mA
135mA
R15
910N
60mA
95 mA
R15Ex
1
x
2
x
3
RP15
7
910P
75mA
100mA
RP15Ex
1
x
2
x
3
910L
110mA
135mA
R40
7
920N
65mA
95mA
R40Ex
1
x
2
x
3
RP40
7
920P
85mA
100mA
RP40Ex
1
x
2
x
3
920L
120mA
145mA
RK40
921N
5.5 - 16VDC
85mA
100mA
220mA
RK40Ex
1
x
2
x
3
RPK40
7
921P
95mA
105mA
RPK40Ex
1
x
2
x
3
921L
130mA
155mA
BTSmart Specifications
OPERATING TEMPERATURE
FREQUENCY
FCC & IC IDS
-15° to 150° F (-25° to 65° C)
2.4 - 2.480 GHz
FCC-ID: JQ6-ICLASSBTM
IC-ID: 2236B-ICLASSBTM
The final product, containing the modular transmitter must be labeled with its own FCC ID and IC ID. If the FCC & IC ID is not visible, when the module
is installed inside another device, then the final assembly label must contain the FCC and IC ID numbers with a statement such as follows: “Contains
Transmitter Module with FCC ID JQ6-ICLASSBTM and IC ID 2236B-ICLASSBTM”.
1 Communication protocols other than Wiegand or Clock & Data
(for control panels), as well as credential interfaces over BLE
(not applicable for 9xxL models), require an additional
hardware module which increases current by
4
0mA.
2 Standby AVG - RMS current draw without a card in the RF field.
3 Maximum AVG - RMS current draw during continuous card reads.
Not evaluated by UL.
4 Peak - highest instantaneous current draw during RF communication.
5 When configured for Bluetooth Operating Range is -13° to 150° F
(-25° to 65° C)
6 Wiegand Cable Lengths:
100 ft (30.5 m) 22 AWG @ 5 - 6.4VDC
500 ft (152 m) 22 AWG @ 6.5 - 16VDC
7 Mobile Enabled Products, see specifications below.
UL Reference Number Deciphering
x
1
Reader Colors:
K = Black
x
2
Wiring:
N = Pigtail
T = Terminal
5 = 5 meter Pigtail
x
3
Communications:
N = No Module
R = RS-485 (OSDP)
L = Indala Prox
B = Bluetooth