678
Auxiliary Area Allocations by Address
Appendix D
A738 to
A740
All
Power ON
Clock Data 7
These words contain the time at which
the power was turned ON seven times
before the startup time stored in words
A510 to A511.
A738.00 to A738.07: Seconds (00 to 59)
A738.08 to A738.15: Minutes (00 to 59)
A739.00 to A739.07: Hour (00 to 23)
A739.08 to A739.15: Day of month (00
to 31)
A740.00 to A740.07: Month (01 to 12)
A740.08 to A740.15: Year (00 to 99)
See at left.
Retained Retained Written
when
power is
turned
ON.
A741 to
A743
All
Power ON
Clock Data 8
These words contain the time at which
the power was turned ON eight times
before the startup time stored in words
A510 to A511.
A741.00 to A741.07: Seconds (00 to 59)
A741.08 to A741.15: Minutes (00 to 59)
A742.00 to A742.07: Hour (00 to 23)
A742.08 to A742.15: Day of month (00
to 31)
A743.00 to A743.07: Month (01 to 12)
A743.08 to A743.15: Year (00 to 99)
See at left.
Retained Retained Written
when
power is
turned
ON.
A744 to
A746
All
Power ON
Clock Data 9
These words contain the time at which
the power was turned ON nine times
before the startup time stored in words
A510 to A511.
A744.00 to A744.07: Seconds (00 to 59)
A744.08 to A744.15: Minutes (00 to 59)
A745.00 to A745.07: Hour (00 to 23)
A745.08 to A745.15: Day of month (00
to 31)
A746.00 to A746.07: Month (01 to 12)
A746.08 to A746.15: Year (00 to 99)
See at left.
Retained Retained Written
when
power is
turned
ON.
A747 to
A749
All
Power ON
Clock Data
10
These words contain the time at which
the power was turned ON ten times
before the startup time stored in words
A510 to A511.
A747.00 to A747.07: Seconds (00 to 59)
A747.08 to A747.15: Minutes (00 to 59)
A748.00 to A748.07: Hour (00 to 23)
A748.08 to A748.15: Day of month (00
to 31)
A749.00 to A749.07: Month (01 to 12)
A749.08 to A749.15: Year (00 to 99)
See at left.
Retained Retained Written
when
power is
turned
ON.
A751
A751.11 DM Initial
Values Read
Error Flag
ON when an error occurred in transfer-
ring DM initial values from the DM initial
value area in flash memory to the DM
Area.
OFF: Normal
ON: Error
(failed to load)
Retained Cleared
---
---
A751.12 DM Initial
Values Save
Execution
Error Flag
ON when the DM Initial Values Transfer
Password (A752) is incorrect or when
the DM Initial values area was not spec-
ified when starting to transfer DM initial
values from the DM Area to the DM ini-
tial value area in flash memory.
OFF: Normal
ON: Error
(failed to save)
Retained Cleared
---
---
A751.13 DM Initial
Values Save
Error Flag
ON when an error occurred in transfer-
ring DM initial values from the DM Area
to the DM initial value area in flash
memory.
OFF: Normal
ON: Error
(failed to save)
Retained Cleared
---
---
A751.14 DM Initial
Values Save
Flag
ON while DM initial values are being
transferred from the DM Area to the DM
initial value area in flash memory.
OFF when the transfer has been com-
pleted.
OFF: Not being
saved
ON: Being
saved
Retained Cleared
---
---
A751.15 DM Initial
Values Save
Start Bit
Turn ON this bit to start transferring DM
initial values. This bit is valid only when
a correct password is stored in A752
and the DM Area Initial Value Area is
specified (i.e., when A753.00 is ON).
The system will turn this bit OFF auto-
matically when the transfer has been
completed.
Turned ON:
Transfer
started
OFF: Not trans-
ferring
ON: Transfer-
ring
Retained Cleared
---
---
Addresses
Name
Function
Settings
Status
after
mode
change
Status
at star-
tup
Write
timing
Related
Flags,
Settings
Word
Bits
Содержание CP1H CPU UNITS - PROGRAMMING 05-2007
Страница 2: ......
Страница 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Страница 4: ...iv...
Страница 10: ...x...
Страница 18: ...xviii...
Страница 22: ...xxii...
Страница 34: ...xxxiv Conformance to EC Directives 6...
Страница 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Страница 370: ...336 Analog I O XA CPU Units Section 5 5...
Страница 552: ...518 Trouble Shooting Section 8 7...
Страница 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Страница 598: ...564 Sample Application Section 9 12...
Страница 642: ...608 Standard Models Appendix A...
Страница 643: ...609 Appendix B Dimensions Diagrams X XA and Y CPU Units 90 100 110 140 150 8 85 Four 4 5 dia holes...
Страница 652: ...618 Dimensions Diagrams Appendix B...
Страница 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Страница 776: ...742 PLC Setup Appendix G...
Страница 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Страница 786: ...752 Revision History...