165
Timers and Counters
Section 4-13
Examples
In this example, a TR bit is used when two outputs have been directly con-
nected to a branch point.
In this example, a TR bit is used when an output is connected to a branch
point without a separate execution condition.
Note
A TR bit is not required when there are no execution conditions after the
branch point or there is an execution condition only in the last line of the
instruction block.
4-13 Timers and Counters
4-13-1 Timer Area (T)
The 4,096 timer numbers (T0000 to T4095) are shared by the TIM,
TIMX(550), TIMH(015), TIMHX(551), TMHH(540), TIMHHX(552), TTIM(087),
TTIMX(555), TIMW(813), TIMWX(816), TMHW(815), and TIMHWX(817)
instructions. Timer Completion Flags and present values (PVs) for these
instructions are accessed with the timer numbers.
The TIML(542), TIMLX(553), MTIM(543), and MTIMX(554) instructions do not
use timer numbers.
When a timer number is used in an operand that requires bit data, the timer
number accesses the Completion Flag of the timer. When a timer number is
used in an operand that requires word data, the timer number accesses the
PV of the timer. Timer Completion Flags can be used as often as necessary
as normally open and normally closed conditions and the values of timer PVs
can be read as normal word data.
LD
OR
OUT
AND
OUT
LD
AND
OUT
0.00
0.01
TR 0
0.02
0.03
TR 0
0.04
0.05
Instruction
Operand
TR0
0.00
0.05
0.01
0.02
0.04
0.03
LD
OUT
AND
OUT
LD
OUT
0.00
TR 0
0.01
0.02
TR 0
0.03
Instruction
Operand
TR0
0.00
0.01
0.02
0.03
LD
0.00
OUT
0.01
AND
OUT
0.02
0.03
LD
0.00
OUT
OUT
0.01
0.02
Instruction
Operand
Instruction
Operand
0.00
0.01
0.02
0.00
0.01
0.03
0.02
Содержание CP1H CPU UNITS - PROGRAMMING 05-2007
Страница 2: ......
Страница 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Страница 4: ...iv...
Страница 10: ...x...
Страница 18: ...xviii...
Страница 22: ...xxii...
Страница 34: ...xxxiv Conformance to EC Directives 6...
Страница 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Страница 370: ...336 Analog I O XA CPU Units Section 5 5...
Страница 552: ...518 Trouble Shooting Section 8 7...
Страница 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Страница 598: ...564 Sample Application Section 9 12...
Страница 642: ...608 Standard Models Appendix A...
Страница 643: ...609 Appendix B Dimensions Diagrams X XA and Y CPU Units 90 100 110 140 150 8 85 Four 4 5 dia holes...
Страница 652: ...618 Dimensions Diagrams Appendix B...
Страница 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Страница 776: ...742 PLC Setup Appendix G...
Страница 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Страница 786: ...752 Revision History...