Features and Main Functions
Section 1-1
Target Speed, Acceleration Rate, and Deceleration Rate Changes during
Acceleration or Deceleration
When a PULSE OUTPUT instruction with trapezoidal acceleration and decel-
eration is executed (for speed control or positioning), the target speed and
acceleration and deceleration rates can be changed during acceleration or
deceleration.
Lighting and Power Control by Outputting Variable Duty Ratio Pulses
Operations, such as lighting and power control, can be handled by outputting
variable duty ratio pulse (PWM) output signals from the CPU Unit's built-in
outputs.
Origin Searches (All
Models)
Origin Search and Origin Return Operations Using a Single Instruction
An accurate origin search combining all I/O signals (origin proximity input sig-
nal, origin input signal, positioning completed signal, error counter reset out-
put, etc.) can be executed with a single instruction. It is also possible to move
directly to an established origin using an origin return operation.
Input Interrupts (All
Models)
In direct mode, an interrupt task can be started when a built-in input turns ON
or OFF. In counter mode, the rising or falling edges of built-in inputs can be
counted, and an interrupt task started when the count reaches a specified
value. The maximum number of points is 8 for X and XA CPU Units and 6 for
Y CPU Units. (See note.)
Note
For each input point, a selection in the PLC Setup determines whether it is to
be used as a normal input, interrupt input, quick-response input, or high-
speed counter. The interrupt input response frequency in counter mode must
be 5 kHz or less total for all interrupts.
Quick-response
Inputs (All Models)
By using quick-response inputs, built-in inputs up to a minimum input signal
width of 30
µ
s can be read regardless of the cycle time.
The maximum number of points is 8 for X and XA CPU Units and 6 for Y CPU
Units. (See note.)
Note
For each input, a PLC Setup parameter determines whether it is to be used as
a normal input, interrupt input, quick-response input, or high-speed counter.
Analog I/O Function
(XA CPU Units Only)
XA CPU Units have analog I/O functionality, with 4 analog voltage/current
inputs and 2 analog voltage/current outputs built in.
• A wide range of applications is possible at a resolution of 6,000 or 12,000.
• Application is also possible for process-control sensor input or Inverter
control without using Expansion I/O Units.
0 to 5 V, 1 to 5 V,
0 to 10 V,
−
10 to 10 V
0 to 20 mA, 4 to 20 mA
0 to 5 V, 1 to 5 V,
0 to 10 V,
−
10 to 10 V
0 to 20 mA, 4 to 20 mA
4 analog inputs
2 analog outputs
Inverter, etc.
1
2
3
4
ON
Содержание CP1H CPU UNITS - PROGRAMMING 05-2007
Страница 2: ......
Страница 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Страница 4: ...iv...
Страница 10: ...x...
Страница 18: ...xviii...
Страница 22: ...xxii...
Страница 34: ...xxxiv Conformance to EC Directives 6...
Страница 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Страница 370: ...336 Analog I O XA CPU Units Section 5 5...
Страница 552: ...518 Trouble Shooting Section 8 7...
Страница 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Страница 598: ...564 Sample Application Section 9 12...
Страница 642: ...608 Standard Models Appendix A...
Страница 643: ...609 Appendix B Dimensions Diagrams X XA and Y CPU Units 90 100 110 140 150 8 85 Four 4 5 dia holes...
Страница 652: ...618 Dimensions Diagrams Appendix B...
Страница 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Страница 776: ...742 PLC Setup Appendix G...
Страница 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Страница 786: ...752 Revision History...