34
Connecting Programming Devices
Section 1-3
Reinstalling the USB Driver
1,2,3...
1.
Right-click
USB Device
and select
Delete
from the pop-up menu to delete
the driver.
2.
Reconnect the USB cable. The USB Driver Installation Window will be dis-
played.
3.
Reinstall the USB driver.
Restrictions when
Connecting by USB
In conformity with USB specifications, the following restrictions apply when
connecting a computer running Support Software.
• A USB connection is possible for only one CP1H from a single computer.
It is not possible to connect multiple CP1Hs simultaneously.
• Do not disconnect the USB cable while the Support Software is con-
nected online. Before disconnecting the USB cable, be sure to place the
application in offline status. If the USB cable is disconnected while online,
the situations described below will occur as a result of OS error.
• Windows Me, 2000, or XP:
The Support Software cannot be returned to online status by simply re-
connecting the USB cable. First return the Support Software to offline
status, and then reconnect the USB cable. Then perform the online
connection procedure for the Support Software.
• Windows 98:
If the USB cable is disconnected while online, an error message may
be displayed on a blue screen. If that occurs, it will be necessary to re-
boot the computer.
1-3-2
Connecting to a Serial Port
Mounting a CP1W-CIF01 RS-232C Option Board in a CP1H Option Board
slot makes it possible to connect Support Software with serial communica-
tions, just as with previous models.
Connect the CX-Programmer to the RS-232C port of the CP1W-CIF01 Option
Board by XW2Z-200S-CV/500S-CV RS-232C cable.
SYSMAC
CP1H
BATTERY
MEMORY
PERIPHERAL
POWER
ERR/ALM
BKUP
RUN
INH
PRPHL
100CH
101CH
COMM
COMM
EXP
L1
L2/N
COM
0CH
1CH
01
03
05
07
09
11
01
03
05
07
09
11
00
02
04
06
08
10
00
02
04
06
08
10
00
01
02
03
04
06
00
01
03
04
06
COM
COM
COM
COM
05
07
COM
02
COM
05
07
IN
OUT
Personal computer
CX-One (e.g., CX-Programmer)
D-Sub connector
(9-pin, female)
D-Sub connector
(9-pin, male)
Recommended cable
XW2Z-200S-CV (2 m) or
XW2Z-500S-CV (5 m)
CP1W-CIF01
RS-232C Option Board
Содержание CP1H CPU UNITS - PROGRAMMING 05-2007
Страница 2: ......
Страница 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Страница 4: ...iv...
Страница 10: ...x...
Страница 18: ...xviii...
Страница 22: ...xxii...
Страница 34: ...xxxiv Conformance to EC Directives 6...
Страница 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Страница 370: ...336 Analog I O XA CPU Units Section 5 5...
Страница 552: ...518 Trouble Shooting Section 8 7...
Страница 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Страница 598: ...564 Sample Application Section 9 12...
Страница 642: ...608 Standard Models Appendix A...
Страница 643: ...609 Appendix B Dimensions Diagrams X XA and Y CPU Units 90 100 110 140 150 8 85 Four 4 5 dia holes...
Страница 652: ...618 Dimensions Diagrams Appendix B...
Страница 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Страница 776: ...742 PLC Setup Appendix G...
Страница 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Страница 786: ...752 Revision History...