414
Analog I/O Units
Section 7-4
Setting D/A Conversion Data
Output data is written to the Analog I/O Unit’s allocated output word, word
n+1.
Note
Word (n + 1) can be used for either the range code or the analog output set
value.
1,2,3...
1.
The set value range is 0000 to 00FF hex when the output signal range is 0
to 10 V/4 to 20 mA.
2.
The set value range is divided into two parts: 8000 to 80FF hex (
−
10 to 0
V) and 0000 to 00FF hex (0 to 10 V) when the output signal range is
−
10
to 10 V.
3.
If FF
@@
is input, 0 V/4 mA will be output.
4.
If an output value is specified, the following bits will be ignored.
• Output range of
−
10 to 10 V: Bits 08 to 14
• Output range of 0 to 10 V/4 to 20 mA: Bits 08 to 15
Startup Operation
After power is turned ON, it will require two cycle times plus approx. 100 ms
before the first data is converted. The following instructions can be placed at
the beginning of the program to delay reading converted data from analog
inputs until conversion is actually possible.
Analog input data will be 0000 until initial processing has been completed.
Analog output data will be 0 V or 0 mA until the range code has been written.
After the range code has been written, the analog output data will be 0 V or
4 mA if the range is 0 to 10 V,
−
10 to 10 V, or 4 to 20 mA.
MOV(21)
MOVE instruction
Ladder program
Word n + 1
CPU Unit
Analog I/O Unit
(See note.)
•
Writes the range code
•
Writes the set value
Range code
Analog output set value
"n" is the last output word allocated to the CPU
Unit, or previous Expansion Unit or Expansion I/O
Unit.
Analog devices
•
Adjustment equipment
•
Servo Controller
•
Variable speed device
•
Recorder
•
Other
n + 1
15
00
Sign bit
(Used when the
output signal range is
−
10 to 10 V.)
Set value (00 to FF hex)
Содержание CP1H CPU UNITS - PROGRAMMING 05-2007
Страница 2: ......
Страница 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Страница 4: ...iv...
Страница 10: ...x...
Страница 18: ...xviii...
Страница 22: ...xxii...
Страница 34: ...xxxiv Conformance to EC Directives 6...
Страница 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Страница 370: ...336 Analog I O XA CPU Units Section 5 5...
Страница 552: ...518 Trouble Shooting Section 8 7...
Страница 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Страница 598: ...564 Sample Application Section 9 12...
Страница 642: ...608 Standard Models Appendix A...
Страница 643: ...609 Appendix B Dimensions Diagrams X XA and Y CPU Units 90 100 110 140 150 8 85 Four 4 5 dia holes...
Страница 652: ...618 Dimensions Diagrams Appendix B...
Страница 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Страница 776: ...742 PLC Setup Appendix G...
Страница 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Страница 786: ...752 Revision History...