630
Auxiliary Area Allocations by Function
Appendix C
Clock
Clock Information
Note
The clock data is stored in the CPU Unit as BCD.
Operation Start and End Times
Option Board Error Flag
A315.13
ON when the Option Board is removed while the power is
being supplied.
CPU Unit operation will continue and the ERR/ALM indi-
cator will flash.
OFF when the error has been cleared.
Read-only
When an error
occurs
Built-in Analog I/O Error
Flag
A315.14
ON when a built-in analog I/O error occurs and stops the
operation of built-in analog I/O.
CPU Unit operation will continue and the ERR/ALM indi-
cator will flash.
OFF when the error has been cleared.
Read-only
When an error
occurs
Flash Memory Error Flag
A315.15
ON when writing to the internal flash memory fails.
CPU Unit operation will continue and the ERR/ALM indi-
cator will flash.
OFF when the error has been cleared.
Read-only
When an error
occurs
Other Fatal Error Flag
A402.00
ON when a non-fatal error that is not defined for A402.01
to A402.15 occurs. Detailed information is output to the
bits of A314.
OFF: No other fatal error
ON: Other fatal error
Read-only
When an error
occurs
Name
Address
Description
Access
Updated
Clock Data
The clock data from the clock built into the CPU Unit is stored here in BCD.
Read-only
A351.00 to A351.07
Seconds: 00 to 59 (BCD)
A351.08 to A351.15
Minutes: 00 to 59 (BCD)
A352.00 to A352.07
Hour: 00 to 23 (BCD)
A352.08 to A352.15
Day of the month: 01 to 31 (BCD)
A353.00 to A353.07
Month: 01 to 12 (BCD)
A353.08 to A353.15
Year: 00 to 99 (BCD)
A354.00 to A354.07
Day of the week: 00: Sunday, 01: Monday, 02: Tuesday,
03: Wednesday, 04: Thursday, 05: Friday, 06: Saturday
Name
Address
Description
Access
Updated
Operation Start Time
A515 to
A517
The time that operation started as a result of changing
the operating mode to RUN or MONITOR mode is stored
here in BCD.
A515.00 to A515.07: Seconds (00 to 59)
A515.08 to A515.15: Minutes (00 to 59)
A516.00 to A516.07: Hour (00 to 23)
A516.08 to A516.15: Day of month (01 to 31)
A517.00 to A517.07: Month (01 to 12)
A517.08 to A517.15: Year (00 to 99)
Note
The previous start time is stored after turning ON
the power supply until operation is started.
Read/write
Operation End Time
A518 to
A520
The time that operation stopped as a result of changing
the operating mode to PROGRAM mode is stored here in
BCD.
A518.00 to A518.07: Seconds (00 to 59)
A518.08 to A518.15: Minutes (01 to 59)
A519.00 to A519.07: Hour (00 to 23)
A519.08 to A519.15: Day of month (01 to 31)
A520.00 to A520.07: Month (01 to 12)
A520.08 to A520.15: Year (00 to 99)
Note
If an error occurs in operation, the time of the
error will be stored. If the operating mode is then
changed to PROGRAM mode, the time that PRO-
GRAM mode was entered will be stored.
Read/write
Name
Address
Description
Access
Updated
Содержание CP1H CPU UNITS - PROGRAMMING 05-2007
Страница 2: ......
Страница 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Страница 4: ...iv...
Страница 10: ...x...
Страница 18: ...xviii...
Страница 22: ...xxii...
Страница 34: ...xxxiv Conformance to EC Directives 6...
Страница 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Страница 370: ...336 Analog I O XA CPU Units Section 5 5...
Страница 552: ...518 Trouble Shooting Section 8 7...
Страница 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Страница 598: ...564 Sample Application Section 9 12...
Страница 642: ...608 Standard Models Appendix A...
Страница 643: ...609 Appendix B Dimensions Diagrams X XA and Y CPU Units 90 100 110 140 150 8 85 Four 4 5 dia holes...
Страница 652: ...618 Dimensions Diagrams Appendix B...
Страница 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Страница 776: ...742 PLC Setup Appendix G...
Страница 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Страница 786: ...752 Revision History...