PN 9033946

Page 1 of 5

DFE Series Module

Memory Upgrade Kit (DFE-256MB-UGK)

Installation Instructions

Before You Begin

These installation instructions describe how to upgrade the Dual-Inline Memory Module (DIMM) 
on a DFE series module from 128 MB to 256 MB using the 256 MB SDRAM DIMM included in this 
DFE-256MB-UGK

 

kit.

To help eliminate any potential problems during or after installation, read and understand all of 
the instructions in this document and in the release notes supplied with the DFE-256MB-UGK 
upgrade kit. 

If there are missing or damaged parts, or you need help installing the DIMM, contact Enterasys 
Networks for assistance. (Refer to “

Getting Help

” at the end of this document.)

Kit Parts

Required Tools

Caution: 

Only authorized personnel should install the DFE Series Module Memory Upgrade Kit 

(DFE-256MB-UGK).

Note: 

Access to advanced routing features, such as Protocol Independent Multicasting 

(PIM) and Load Share Network Address Translation (LSNAT) currently require memory 
greater than 128 MB. Please consult the Release Notes to see which additional features 
require this memory upgrade.

Qty

Item

1

256 MB SDRAM DIMM assembly

1

URL Location Card

1

This document (PN 9033946)

Qty

Item

1

Antistatic wrist strap (not supplied)

Содержание DFE-256MB-UGK

Страница 1: ...ade kit If there are missing or damaged parts or you need help installing the DIMM contact Enterasys Networks for assistance Refer to Getting Help at the end of this document Kit Parts Required Tools Caution Only authorized personnel should install the DFE Series Module Memory Upgrade Kit DFE 256MB UGK Note Access to advanced routing features such as Protocol Independent Multicasting PIM and Load ...

Страница 2: ... for instructions to remove the daughter board To replace a DIMM proceed to DIMM Replacement Procedure below Caution To prevent damage from static discharge use an antistatic wrist strap and observe all static precautions during this procedure Failure to do so could result in damage to the DIMM module or both 9 Tip Before performing step 2 mark the cables connected to the DFE Series Module accordi...

Страница 3: ...ure 2 and proceed as follows 1 With the connector arms set in the open position insert the DIMM between the connector fingers 2 Push the memory module into the connector until the tabs on the two connector arms pull in towards the DIMM alignment notches Caution Observe all antistatic precautions when handling sensitive electronic equipment Connector arms DIMM Connector  À À Á Caution Observe all ...

Страница 4: ...E module If you are not familiar with the proper procedure to install a DFE module refer to the DFE Installation Guide for module installation instructions 3 Disconnect the antistatic wrist strap ground lead 4 Note the cable labeling done before removing the cables and reconnect the cables accordingly 5 The upgraded memory module is now ready for operation Caution If the DIMM is not firmly locked ...

Страница 5: ...n Material Authorization RMA numbers Enterasys Networks Inc 50 Minuteman Road Andover MA 01810 2004 Enterasys Networks Inc All rights reserved Part Number 9033946 February 2004 ENTERASYS NETWORKS ENTERASYS MATRIX LANVIEW WEBVIEW and any logos associated therewith are trademarks or registered trademarks of Enterasys Networks Inc in the United States and other countries All other product names menti...

Отзывы: