343
Serial Communications
Section 6-1
Modbus-RTU commands can be set simply by turning ON a software switch
after setting the Modbus slave address, function, and data in the DM fixed
allocation words for the Modbus-RTU Easy Master. The response when
received is also store in the DM fixed allocation words for the Modbus-RTU
Easy Master.
DM Fixed Allocation
Words for the
Modbus-RTU Easy
Master
Modbus-RTU commands are stored in the DM Area in D32200 to D32249 for
serial port 1 and in D32300 to D32349 for serial port 2. When a response is
received after turning ON the Modbus-RTU Master Execution Bit, it is stored
in D32250 to D32299 for serial port 1 and in D32350 to D32399 for serial port
2.
08
07
00
D32200
D32201
D32202
D32203
OMRON Inverters
3G3JV, 3G3MV, or 3G3RV
Communications are easily achieved by simply by
turning ON a software switch after setting the
Modbus-RTU command in the DM fixed allocation
words.
Slave address
Function code
Number of communications data bytes
Communications data
15
:
:
Slave address
Function code
Communications data
Slave address
Function code
Communications data
Modbus-RTU Master
Execution Bit for Port 1
A640.00
Modbus-RTU
Modbus-RTU
Words
Bits
Contents
Serial
port 1
Serial
port 2
D32200
D32300
00 to 07
Command
Slave address (00 to F7 hex)
08 to 15
Reserved (Always 00.)
D32201
D32301
00 to 07
Function code
08 to 15
Reserved (Always 00.)
D32202
D32302
00 to 15
Number of communications data
bytes (0000 to 005E hex)
D32203 to
D32249
D32303 to
D32349
00 to 15
Communications data
(94 bytes maximum)
D32250
D32350
00 to 07
Response
Slave address (00 to F7 hex)
08 to 15
Reserved (Always 00.)
D32251
D32351
00 to 07
Function code
08 to 15
Reserved
D32252
D32352
00 to 07
Error code
08 to 15
Reserved (Always 00.)
D32253
D32353
00 to 15
Number of response bytes (0000
to 03EA hex)
D32254 to
D32299
D32354 to
D32399
00 to 15
Response data
(92 bytes maximum)
Содержание CP1H CPU UNITS - PROGRAMMING 05-2007
Страница 2: ......
Страница 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Страница 4: ...iv...
Страница 10: ...x...
Страница 18: ...xviii...
Страница 22: ...xxii...
Страница 34: ...xxxiv Conformance to EC Directives 6...
Страница 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Страница 370: ...336 Analog I O XA CPU Units Section 5 5...
Страница 552: ...518 Trouble Shooting Section 8 7...
Страница 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Страница 598: ...564 Sample Application Section 9 12...
Страница 642: ...608 Standard Models Appendix A...
Страница 643: ...609 Appendix B Dimensions Diagrams X XA and Y CPU Units 90 100 110 140 150 8 85 Four 4 5 dia holes...
Страница 652: ...618 Dimensions Diagrams Appendix B...
Страница 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Страница 776: ...742 PLC Setup Appendix G...
Страница 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Страница 786: ...752 Revision History...