189
Interrupt Functions
Section 5-1
Input Terminal Arrangement
Setting the Input Functions in the PLC Setup
Normally, bits CIO 0.00 to CIO 0.03 and CIO 1.00 to CIO 1.03 are used as
normal inputs. When using these inputs for input interrupts, use the CX-Pro-
grammer to change the input’s setting in the PLC Setup.
Y CPU Units
The 6 input bits CIO 0.00 to CIO 0.01 and CIO 1.00 to CIO 1.03 can be used
for input interrupts.
Input Terminal Arrangement
Input terminal
block
Input operation setting
Task number
Word
Bit
Normal inputs
Input interrupt
CIO 0
00
Normal input 0
Input interrupt 0
Interrupt task 140
01
Normal input 1
Input interrupt 1
Interrupt task 141
02
Normal input 2
Input interrupt 2
Interrupt task 142
03
Normal input 3
Input interrupt 3
Interrupt task 143
04 to 11
Normal inputs 4 to 11
---
---
CIO 1
00
Normal input 12
Input interrupt 4
Interrupt task 144
01
Normal input 13
Input interrupt 5
Interrupt task 145
02
Normal input 14
Input interrupt 6
Interrupt task 146
03
Normal input 15
Input interrupt 7
Interrupt task 147
04 to 11
Normal inputs 16 to 23 ---
---
00
02
04 06 08 10 00
02
04 06 08 10
L1 L2/N
COM
01 03 05 07 09 11 01 03 05 07 09 11
LG
Input interrupt 0
Input interrupt 2
Input interrupt 3
Input interrupt 1
Input interrupt 7
Input interrupt 5
Input interrupt 4
Input interrupt 6
Inputs (CIO 0)
Inputs (CIO 1)
Upper Terminal Block
(Example: AC Power
Supply Modules)
NC
A0
−
B0
−
Z0
−
A1
−
B1
−
Z1
−
00
04 10 00
02
04
+
−
A0+ B0+ Z0+ A1+ B1+ Z1+ COM 01 05 11 01 03 05
Upper Terminal Block
Input
interrupt 3
Inputs (CIO 0)
Inputs (CIO 1)
Input
interrupt 5
Input
interrupt 4
Input
interrupt 2
Input
interrupt 0
Input
interrupt 1
High-speed counter terminals
High-speed counter terminals
Содержание CP1H CPU UNITS - PROGRAMMING 05-2007
Страница 2: ......
Страница 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Страница 4: ...iv...
Страница 10: ...x...
Страница 18: ...xviii...
Страница 22: ...xxii...
Страница 34: ...xxxiv Conformance to EC Directives 6...
Страница 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Страница 370: ...336 Analog I O XA CPU Units Section 5 5...
Страница 552: ...518 Trouble Shooting Section 8 7...
Страница 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Страница 598: ...564 Sample Application Section 9 12...
Страница 642: ...608 Standard Models Appendix A...
Страница 643: ...609 Appendix B Dimensions Diagrams X XA and Y CPU Units 90 100 110 140 150 8 85 Four 4 5 dia holes...
Страница 652: ...618 Dimensions Diagrams Appendix B...
Страница 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Страница 776: ...742 PLC Setup Appendix G...
Страница 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Страница 786: ...752 Revision History...