Chapter 5
5-24
Remote I/O Functions
●
Input Bit Details
Note 1.
The function set in the multi-function output selection parameter is enabled.
3G3MV: The function set in parameter n057 to n059 (function selection for multi-function outputs 1
to 3) is enabled.
3G3RV/3G3PV/3G3FV:
The function set in parameter H2-01 to H2-03 (function selection for the multi-function con-
tact output and multi-function outputs 1 and 2) is enabled.
Note 2.
The P lock function (position lock or zero-servo function) is valid only for a 3G3FV Inverter
operating with flux vector control. This bit is not used with other Inverters or control modes.
Name
Function
During run
1: During run
Zero speed
1: Zero speed
During reverse run
1: During reverse run
During reset input
1: During reset input
At reference
1: At reference
Inverter ready
1: Inverter ready
Alarm (minor fault)
1: Alarm (minor fault)
Fault
1: Fault
Operation fault
1: Operation fault
Power interruption
recovery
1: Recovered from a momentary power interruption
Local/remote
1: Remote mode
Multi-function contact
output
1: Function specified in n057/H2-01 (See note 1.)
Multi-function output 1
1: Function specified in n058/H2-02 (See note 1.)
Multi-function output 2
1: Function specified in n059/H2-03 (See note 1.)
P lock completion
1: Position lock engaged (See note 2.)
Содержание 3G3MV-PDRT2
Страница 4: ......
Страница 12: ......
Страница 36: ...Chapter 1 1 22 Functions and System Configuration...
Страница 52: ...Chapter 2 2 16 Example System Startup...
Страница 94: ...Chapter 4 4 14 SYSDRIVE Inverter Settings...
Страница 130: ...Chapter 5 5 36 Remote I O Functions...
Страница 234: ...Chapter 8 8 14 Communications Errors...
Страница 362: ...R 2 Revision History...