Chapter 10
10-54
Appendices
Note 1.
When the control mode is changed, the Inverter will revert to default settings. (The V/f control
default setting is given above.)
Note 2.
The setting range depends on the capacity of the Inverter.
Note 3.
These parameters can be monitored or set only when 1 is set for C6-01 and F is set for C6-
02.
C5-01
021B
02
1B
ASR proportional (P) gain 1
0.00 to
300.00
0.01
0.20
Yes
C5-02
021C
02
1C
ASR integral (I) time 1
0.000 to
10.000
0.001 s
0.200
Yes
C5-03
021D
02
1D
ASR proportional (P) gain 2
0.00 to
300.00
0.01
0.02
Yes
C5-04
021E
02
1E
ASR integral (I) time 2
0.000 to
10.000
0.001 s
0.050
Yes
C5-05
021F
02
1F
ASR limit
0.0 to
20.0
0.1%
5.0
No
C6-01
0223
02
23
CT/VT selection
0, 1
1
1
No
C6-02
0224
02
24
Carrier frequency selection
0 to F
1
Depends
on
capacity.
No
C6-03
0225
02
25
Carrier frequency upper limit
2.0 to
15.0
(See
note 2
and 3.)
0.1 kHz
Depends
on
capacity.
No
C6-04
0226
02
26
Carrier frequency lower limit
0.4 to
15.0
(See
note 2
and 3.)
0.1 kHz
Depends
on
capacity.
No
C6-05
0227
02
27
Carrier frequency proportional gain
00 to 99
(See
note 3.)
1
00
No
Con-
stant
Regis-
ter num-
ber
(hex)
Class 64 (hex)
Name
Setting
range
Setting
unit
Default
setting
Write
during
opera-
tion
In-
stance
At-
tribute
Содержание 3G3MV-PDRT2
Страница 4: ......
Страница 12: ......
Страница 36: ...Chapter 1 1 22 Functions and System Configuration...
Страница 52: ...Chapter 2 2 16 Example System Startup...
Страница 94: ...Chapter 4 4 14 SYSDRIVE Inverter Settings...
Страница 130: ...Chapter 5 5 36 Remote I O Functions...
Страница 234: ...Chapter 8 8 14 Communications Errors...
Страница 362: ...R 2 Revision History...