Chapter 10
10-100
Appendices
Note 1.
The values in parentheses indicate initial values when initialized in 3-wire sequence.
Note 2.
Within the setting range (1 to 38), 4, 10, 11, 12, 13, 14, 25, 28, 34, and 35 cannot be set,
and 29 to 31 are not used.
■
Protective Function Parameters
H3-06
040E
01
8C
Multi-function analog input signal gain:
terminal 16
0.0 to
1000.0
0.1%
100.0
Yes
H3-07
040F
01
8D
Multi-function analog input signal bias:
terminal 16
−
100.0 to
100.0
0.1%
0.0
Yes
H3-08
0410
01
8E
Frequency reference (current) signal
selection: terminal 14
0 to 2
1
2
No
H3-09
0411
01
8F
Frequency reference (current) selec-
tion: terminal 14
0 to 1F
1
1F
No
H3-10
0412
01
90
Frequency reference (current) gain: ter-
minal 14
0.0 to
1000.0
0.1%
100.0
Yes
H3-11
0413
01
91
Frequency reference (current) bias: ter-
minal 14
−
100.0 to
100.0
0.1%
0.0
Yes
H3-12
0414
01
92
Analog input filter time constant
0.00 to
2.00
0.01 s
0.00
No
H4-01
0415
01
93
Multi-function analog output 1 selec-
tion: terminal 21
1 to 38
(See
note 2.)
1
2
No
H4-02
0416
01
94
Multi-function analog output 1 gain ter-
minal 21
0.00 to
2.50
0.01
1.00
Yes
H4-03
0417
01
95
Multi-function analog output 1 bias ter-
minal 21
−
10.0 to
10.0
0.1%
0.0
Yes
H4-04
0418
01
96
Multi-function analog output 2 selec-
tion: terminal 23
1 to 38
(See
note 2.)
1
3
No
H4-05
0419
01
97
Multi-function analog output 2 gain ter-
minal 23
0.00 to
2.50
0.01
0.50
Yes
H4-06
041A
01
98
Multi-function analog output 2 bias ter-
minal 23
−
10.0 to
10.0
0.1%
0.0
Yes
H4-07
041B
01
99
Multi-function analog output signal level
selection
0, 1
1
0
No
H5-01
041C
---
---
Not used.
---
---
1F
---
H5-02
041D
---
---
Not used.
---
---
3
---
H5-03
041E
---
---
Not used.
---
---
0
---
H5-04
041F
---
---
Not used.
---
---
3
---
H5-05
0420
---
---
Not used.
---
---
1
---
Con-
stant
Regis-
ter num-
ber
(hex)
Class 64 (hex)
Name
Setting
range
Setting
unit
Default
setting
Write
during
opera-
tion
In-
stance
At-
tribute
L1-01
0480
01
9A
Motor protection selection
0, 1
1
1
No
L1-02
0481
01
9B
Motor protection time constant
0.1 to 5.0 0.1 min
1.0
No
L2-01
0482
04
9C
Momentary power loss selection
0 to 2
1
0
No
L2-02
0483
01
9D
Momentary power loss ridethru
0.0 to 2.0 0.1 s
0.7 (See
note 2.)
No
L2-03
0484
01
9E
Minimum baseblock time (BB)
0.1 to 5.0 0.1 s
0.5 (See
note 2.)
No
Con-
stant
Regis-
ter num-
ber
(hex)
Class 64 (hex)
Name
Setting
range
Setting
unit
Default
setting
Write
during
opera-
tion
In-
stance
At-
tribute
Содержание 3G3MV-PDRT2
Страница 4: ......
Страница 12: ......
Страница 36: ...Chapter 1 1 22 Functions and System Configuration...
Страница 52: ...Chapter 2 2 16 Example System Startup...
Страница 94: ...Chapter 4 4 14 SYSDRIVE Inverter Settings...
Страница 130: ...Chapter 5 5 36 Remote I O Functions...
Страница 234: ...Chapter 8 8 14 Communications Errors...
Страница 362: ...R 2 Revision History...