Chapter 7
7-31
Configurator Settings
■
Monitoring Methods
●
Using the Monitor Device Window
• Click the
OUT
Tab or
IN
Tab in the Monitor Device Window to monitor in outputs/inputs.
• The following information will be displayed.
Note 1.
The monitoring items in the IN Tab Page are similar to the OUT Tab Page. The numeric val-
ues in the
No.
field, however, indicate each input terminal. (Refer to page 7-29.)
Note 2.
The ON/OFF status of the Connected Component Maintenance Flag can be checked on the
General Tab Page of the Monitor Device Window. When this flag is ON, the
Connected Com-
ponent Maintenance
check box will be selected.
Item
Details
No.
The settings in the
No.
field are as follows:
00: Multi-function contact output, 01: Multi-function output 1, 02: Multi-function
output 2
Note: When the present value of the maintenance counter (total ON time or con-
tact operations counter) exceeds the monitor value, the error icon is displayed on
the left side of the corresponding No. setting.
I/O Comment
Displays the comment for the connected device for each output terminal.
ON/OFF
Displays the ON/OFF status (present value status) for each output terminal.
Maintenance Counter
Displays the present value of the maintenance counter for each output terminal.
Note: The total ON time (s) or contact operations count (No. of times) is dis-
played.
Clear Value Button
Clears the present value of the maintenance counter to zero.
Note: Select the terminal to be cleared, click the
Clear Value
Button to clear the
value to zero.
OUT Tab Page in the
Monitor Device
Window
Содержание 3G3MV-PDRT2
Страница 4: ......
Страница 12: ......
Страница 36: ...Chapter 1 1 22 Functions and System Configuration...
Страница 52: ...Chapter 2 2 16 Example System Startup...
Страница 94: ...Chapter 4 4 14 SYSDRIVE Inverter Settings...
Страница 130: ...Chapter 5 5 36 Remote I O Functions...
Страница 234: ...Chapter 8 8 14 Communications Errors...
Страница 362: ...R 2 Revision History...