Chapter 1
1-21
Functions and System Configuration
Allocation areas
Core I/O Area:
CIO 0000 to CIO 2555
CIO 0000 to CIO 2427
for CV500/CVM1-
CPU01(-V
@
)
IR Area 1: IR 000 to IR 235
IR Area 2: IR 300 to IR 511
CPU Bus Link Area:
G008 to G255
CS Series
HR: H000 to H099
CIO: 1000 to 1063
C200HX/HG/HE
HR Area: HR 00 to HR
99
LR Area: LR 00 to LR 63
HR Area:
HR 00 to HR 99
LR Area:
LR 00 to LR 63
DM Area:
D00000 to D24575
D00000 to D08191 for
CV500/CVM1-CPU01 (-
V
@
)
CS Series
DM: D00000 to D05999
C200HX/HG/HE
DM: DM 0000 to DM
5999
(DM 0000 to DM 4095
for C200HE-CPU11-
(Z)E)
DM Area:
DM 0000 to DM 5999
Allocation method
Words are allocated to each node in the above data areas in any order using
the Configurator.
The following limitations apply:
• The allocation areas are in 4 blocks (OUT 1, OUT 2, IN 1, and IN 2). Each
block consists of sequential words.
• 100 words max. per block.
• For Slaves with more than 8 points, the first byte cannot be specified in
leftmost bits (7 to 15).
Words are allocated to Slaves as follows:
• 8-point Slaves: Allocated leftmost or rightmost byte of 1 word
• 16-point Slaves: Allocated 1 word
• Slaves with more than 16-points: Allocated multiple words (For Slaves with
an odd number of bytes, the last byte will be the rightmost byte)
Maximum
number of
Inverters
(using one
DeviceNet
(Master) Unit
only)
Without
explicit mes-
sages
63
4 remote I/O words: 63
6 remote I/O words: 50
8 remote I/O words: 37
4 words remote I/O: 20
6 words remote I/O: 13
8 remote I/O words: 10
With explicit
messages
63
4 remote I/O words: 25
6 remote I/O words: 16
8 remote I/O words: 12
---
Maximum number of Inverters
with more than one DeviceNet
(Master) Unit
Calculate from the number of words allocated in the data areas and the
number of words allocated to the Inverters (4 or 6 words).
Note 1.
The DM Area cannot be manipulated by bit, so it cannot be allo-
cated for remote I/O for Inverters.
Note 2.
If the CPU Bus Link is used with a CVM1/CV-series PLC, the CPU
Bus Link Area will be used for the CPU Bus Link Therefore, the CPU
Bus Link Area cannot be allocated to Inverters for use with
DeviceNet if the CPU Bus Link is used.
Applicable PLC
CVM1/CV Series
CS Series and
C200HX/HG/HE
C200HS
Содержание 3G3MV-PDRT2
Страница 4: ......
Страница 12: ......
Страница 36: ...Chapter 1 1 22 Functions and System Configuration...
Страница 52: ...Chapter 2 2 16 Example System Startup...
Страница 94: ...Chapter 4 4 14 SYSDRIVE Inverter Settings...
Страница 130: ...Chapter 5 5 36 Remote I O Functions...
Страница 234: ...Chapter 8 8 14 Communications Errors...
Страница 362: ...R 2 Revision History...