Chapter 9
9-8
Communications Programs (CS-series PLCs)
000000
003002
003003
003003
ASL(025)
0000
CMND(490)
D02000
D03000
D01000
000001
ASR(026)
0000
ASL(025)
0000
000000
CMP(020)
#0000
D03001
MOV(021)
D03001
D00100
MOV(021)
D03004
D00200
ASR(026)
0000
ASR(026)
0000
000002
003002
MOV(021)
#0000
0000
END(001)
A20200
(Network
Communications
Enabled Flag)
151100
(Online Flag)
Executes CMND instruction.
A21900
(Network
Communications
Error Flag)
Confirms execution of CMND instruction.
Equals Flag
(P_EQ)
The completion code examined. If an
error is found, the command is re-
executed. If the command is executed
normally, the data is stored in D00200.
A20200
(Network
Communications
Enabled Flag)
151100
(Online Flag)
A21900
(Network
Communications
Error Flag)
A20200
(Network
Communications
Enabled Flag)
Equals Flag
(P_EQ)