Chapter 7
7-53
Configurator Settings
7-3-6 Warning Torque Tab Page
Use this tab page to make the settings for warning torque detection.
Item
Details
Reference
Current 1 (during
Accel/Decel)
Set the threshold used to monitor the current level during
acceleration or deceleration.
Note: When this value is set to 0.0 (A), the current is not
monitored during acceleration or deceleration.
7-2-3 Warning Torque
Detection
Current 2 (during
Frequency Agree)
Set the threshold used to monitor the current level during
frequency agreement (while operating at constant speed).
Note: When this value is set to 0.0 (A), the current is not
monitored during frequency agreement.
Detection Filter
Select the
level of
detection sensitivity from
Sensitivity 1
(Low)
to
Sensitivity 5 (High)
in the pull-down menu.
Status
Set whether to maintain the ON status in the Unit’s Status
Area (Warning Torque Detection Flag) when the current
exceeds either of the thresholds set for
Current 1
and
Cur-
rent 2
.