Chapter 7
7-62
Configurator Settings
7-4-7 Inverter Parameters Tab Page
Use this tab page to monitor the following four types of information in the Inverter.
Note
The unit for the frequency reference value and output frequency are determined according to
the set values for the [n035/o1-03] parameter (frequency reference setting and display units).
When the number of motor poles (2 to 39) is set in this parameter, the r/min unit is used. When
the factory setting “0” is used, the x0.01 Hz is used as the unit.
Item
Details
Reference
Speed Reference
Displays the frequency reference value in r/min. (See note.) ---
Speed Actual
Displays the output frequency in r/min. (See note.)
Current Actual
Displays the output current level.
Output Voltage
Displays the output voltage level (Inverter’s internal output
voltage reference value).