Chapter 7
7-52
Configurator Settings
7-3-5 Individual Parameters Tab Page
Use this tab page to set parameters that cannot be set on the Inverter Parameters Tab Page, or to
set individual parameters.
Item
Details
Reference
Instance No.,
Attribute No., and
Value
Set the Instance/Attribute and set value for the parameter to
be changed.
Set the value in hexadecimal.
7-2-14 Parameter Setting
Result
Displays the read result in hexadecimal.
Read Button
Reads the set values of the specified parameter (Instance/
Attribute) from the Inverter.
Write Button
Writes the set parameters to the Inverter.
Note: An error message is displayed when a write error
occurs.
Write to EEPROM
To save the parameter set values in the Inverter even after a
power interruption, select this item before clicking the Write
Button.