NUC126
Aug. 08, 2018
Page
465
of 943
Rev 1.03
NUC12
6 S
E
RI
E
S
T
E
CH
NI
CA
L R
E
F
E
RE
NCE
MA
NUA
L
PWM Period Register 0~5 (PWM_PERIOD0~5)
Register
Offset
R/W
Description
Reset Value
PWM_PERIO
D0
0x30
R/W
PWM Period Register 0
0x0000_0000
PWM_PERIO
D1
0x34
R/W
PWM Period Register 1
0x0000_0000
PWM_PERIO
D2
0x38
R/W
PWM Period Register 2
0x0000_0000
PWM_PERIO
D3
0x3C
R/W
PWM Period Register 3
0x0000_0000
PWM_PERIO
D4
0x40
R/W
PWM Period Register 4
0x0000_0000
PWM_PERIO
D5
0x44
R/W
PWM Period Register 5
0x0000_0000
31
30
29
28
27
26
25
24
Reserved
23
22
21
20
19
18
17
16
Reserved
15
14
13
12
11
10
9
8
PERIOD
7
6
5
4
3
2
1
0
PERIOD
Bits
Description
[31:16]
Reserved
Reserved.
[15:0]
PERIOD
PWM Period Register
Up-Count mode:
In this mode, PWM counter counts from 0 to PERIOD, and restarts from 0.
PWM period time = (1) * (1) * PWMx_CLK.
Down-Count mode:
In this mode, PWM counter counts from PERIOD to 0, and restarts from PERIOD.
PWM period time = (1) * (1) * PWMx_CLK.
Up-Down-Count mode:
In this mode, PWM counter counts from 0 to PERIOD, then decrements to 0 and repeats
again.