NUC126
Aug. 08, 2018
Page
103
of 943
Rev 1.03
NUC12
6 S
E
RI
E
S
T
E
CH
NI
CA
L R
E
F
E
RE
NCE
MA
NUA
L
Bits
Description
[0]
BODEN
Brown-out Detector Enable Bit (Write Protect)
The default value is set by flash controller user configuration register CBODEN (CONFIG0
[23]).
0 = Brown-out Detector function Disabled.
1 = Brown-out Detector function Enabled.
Note:
This bit is write protected. Refer to the SYS_REGLCTL register.