CHAPTER 3 TERMINALS
Issue 5
UNIVERGE NEAX 2000 IPS General Description
Page 209
MP Download Process
Service Conditions
General Service Conditions
The MP program download can be executed to the PN-CP24/PN-CP31 (MP card)
when a PZ-M606-A is mounted.
For the Retrofit and Backup CPU systems remote download of MP program is not
available.
The call processing is stopped while the system is initialized by the program
changeover execution.
Remote download of AP program is not available.
While the PBX is off-line, you cannot execute the program downloading, or program
changeover/changeback/program version matching (immediate). However, it is
possible to read various information and set the schedule (date/time) for program
changeover/changeback/program version matching even while the PBX is off-line.
When the PN-32IPLA is mounted in the system, the MP program download (FTP) is
not available. When the PN-32IPLA-A or PN-8IPLA is mounted, it is available in the
system.
Program Download Service Conditions
Do not reset the PBX and the MATWorX during MP program downloading.
Do not pull out the LAN cable during MP program downloading.
FTP (File Transfer Protocol) is used as the protocol for the remote download of MP
program.
Only the file specified in “File Name” of CHECKSUM.TXT can be downloaded to
the PBX.
If you do not set the directory name to save the program files and CHECKSUM.TXT
by MATWorX, they are saved to the FTP directory (default).
If you do not set the password and user ID of the FTP server by MATWorX, login to
the FTP server with anonymous.
If required FTP server information is not set when executing the MP program
download, “DATA NOT SET” is displayed.
For the TCP port, the specified port is used for file transfer (control), and the port in
front of it is used for the file transfer. For example, when the TCP port is set to 3000,