Ambient Temperature
0 to 40
Relative Humidity
Max. 90% (non-condensing)
7.2.5 Electrical Characteristics (Central Office Trunk
DESCRIPTION
SPECIFICATIONS
Insulation Resistance
15 mega-ohms or more at 100Vdc
DC Resistance
On-hook conditions: 30 mega-ohms
Off-hook conditions: 1,700 ohms
Impedance
On-hook conditions: 20 kilo-ohms (300 to 3,400Hz)
8 kilo-ohms (at 24Hz)
Looped conditions: 600 ohms
Leak Current
0 mA at on-hook conditions
7.2.6 Transmission Characteristics (For TDM Circuits)
DESCRIPTION
SPECIFICATIONS
PCM Coding System
A -law/U -law
Insertion Loss
0.15 dB at 1KHz
Return Loss
20 dB or more (300 to 3,400Hz) against
600 ohms
Longitudinal Balance
59 dB or more (300 to 3,400Hz)
Attenuation/Frequency Distortion
-0.2 dB to +0.7 dB (300 to 3,400Hz)
Group Delay Distortion
0 to 0.3msec. (500 to 2,800 Hz)
Total Distortion
25 dB (Input signal:-45 dBm0)/40 dB
(input signal:0 dBm0)
Idle Channel Noise
-67 dBmop or less (psophometric noise)
-50 dBm0 or less (single frequency noise)
Impulsive Noise
0 counts at -35 dBm
Cross Talk Attenuation
90 dB or more
Inter -modulation Products
-40 dB or more
Spurious In-Band Signals
-49 dBm0 or less
Signal Attenuation
Attenuation rate: 12 dB per octave or
more at 3.4 kHz above
Attenuation level: -40 dBm or less at 3.4
kHz and above -70 dBm or less at 50 kHz