Dterm Series Digital Terminal Options
Adapter Code
Description
CT(A)-R
Connects the Dterm Digital terminals (except the DTR-2DT) to a PC providing
a complete turnkey package with graphical telephone user interface and call
logging. Shipped with Multi-line Phone Kits software. Supports Serial
interface.
AD(A)-R
Provides the Dterm Digital terminals (except the DTR-2DT) with the ability to
interface with a recording device.
AP(R)-R
Provides Dterm Digital terminals (except the DTR-2DT) ability to interface with
analogue device such as a cordless telephone, facsimile machine, external
speakerphone, Automatic Dialer or modem. Provides ringing to analogue
device connected.
AP(A)-R
Provides Dterm Digital terminals (except the DTR-2DT) ability to interface with
analogue device such as a cordless telephone, facsimile machine, external
speakerphone, Automatic Dialer or modem. No ringing is provided.
IP-R
A compact plug-and-play device that installs into the base of a Dterm Digital
terminals (except the DTR-2DT and the DTR-8) ).An integrated two-port
10/100baseT Ethernet pass through hub that permits using one port toconnect
the network interface card (NIC) from the PC to the IP network. The other is
pluggeddirectly into a LAN or an IP network device such as a router, DSL
modem or cable modem.Requires an AC-R ADP.
WM-R
Dterm Digital terminals (except the DTR-2DT) with an AP(R)-R, AP(A)-R,
CT(A)-R, and/or an IP-R Unit can be wall mounted using the WM-R Unit.
Dterm Series i Line Conditions
Cable Length
Note 1
Standard
with AC Adapter
Note 4
8DLC
300m (984ft)
Note 2
4DLC
300m (984ft)
1200m (3937ft)
Dterm 8 / 8D
2DLC
850m (2789ft)
1200m (3937ft)
8DLC
200m (656ft)
Note 2
4DLC
200m (656ft)
1200m (3937ft)
Dterm 16/16D
2DLC
850m (2789ft)
1200m (3937ft)
8DLC
200m (656ft)
Note 2
4DLC
200m (656ft)
1200m (3937ft)
Dterm 32/32D
2DLC
850m (2789ft)
1200m (3937ft)
8DLC
-
300m (984ft)
4DLC
-
1200m (3937ft)
Dterm
Digital
Series
DSS/BLF Console
Note 3
2DLC
-
1200m (3937ft)
Note 1:
Cable length is based on the following conditions.
o
Diameter of the cable is 0.5 mm.
o
The Protection arrester is not inserted between the terminal and PBX.
Note 2:
When using 8DLC card, it is not available for long line function,
even if it is equipped with AC Adapter.
Note 3:
The DSS/BLF Console requires local AC/DC supply.
Note 4: