![Munters Farm P-XL Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/munters/farm-p-xl/farm-p-xl_user-manual_1856887012.webp)
© Munters AB, 2015
12
Scan through Hot Screens for five seconds each
Water and Feed status
Air status (refer page 31 for details on this screen) (Broilers/Layers mode only)
Zone Inlet Position: View the inlet(s) target position, actual position, and number of
steps (refer to page 120 for details) (Layers)
Stir fans status
Increase/ decrease offset from temperature setting from the standard display only
(hold both keys) – defined in the
2.1.4
M
AIN
S
CREEN
D
ISPLAY
The main screen display depends on the operating mode.
NOTE:
When in Layer Mode, refer to Layers Main Screen, page 120.
1. Sensors: Displays individual sensor readings. Temperature sensors marked with dark squares
form the current average temperature.
o
Filled square: Indicates the sensor participates in the average calculation.
o
Empty square: Indicates the sensor does not participate in the average calculation.
SENSORS
AV. TEMP.
ACTIVE
Temp1
37.9°
27.5°
Heat
1
Temp2
16.2°
Heat. Hi
1
Temp3
28.2°
STATUS
Tun. Fan
E. Tmp1
28.8°
08:53:06
Exh. Fan
E. Tmp2
28.4°
Day: 2
Stir
Press.
23
Set:
25.0
Cool P.
Out T.
23.9°
Level:
3
Fogger
Hum. In
58.7%
Min.
Vent
Curt. 1
100%
Hum. Out
61.9%
FanOff:
176
Curt. 2
100%
Weight
0.000
Feeder
Weights
0
Auger
4 MESSAGES
Valve
(2) Low Feed At Bin 2
Alarm