NOTE:
In a three point curve, the intermediate value must be between the cold and warm value in
each line.
3.5.4.2
Weight Hot Screen
Selecting the Ventilation by Weight option enables an additional Hot Screen, the Air Status Screen. This
screen displays the critical parameters involved in the Ventilation by Weight option.
•
Inside Temperature: Current temperature inside the house
•
Outside Temperature: Current temperature outside the house
•
Humidity: Current relative humidity inside the house (requires a humidity sensor)
•
Weight KG: Current average weight of the Bird Curve (page 80)
•
Level: Displays the current, minimum and maximum level of ventilation.
NOTE:
If the current level is below the minimum required level, Farm Premium displays an alarm
“Below Min Air”.
•
Cycle On/Off: Displays the current, minimum and maximum fan on and off times.
•
Total Air M3/h: Displays the current, minimum and maximum quantity of ventilation, per hour.
•
Air/WGT: Displays the current amount of ventilation, per kilo/pound of bird weight.
3.6
Static Pressure
Set target parameters for Static Pressure at High and Low Outside Temperatures, as well as alarms for
high and low static pressure.
In Installation > Setup, enable a static pressure unit.
Refer to Static Pressure Calibration, page 96 and Static Pressure, page 92.
•
Disabling the Static Pressure Sensor
•
Static Pressure Help | Set Definitions
•
AIR STATUS
Inside Temp
Outside Temp
Humidity
Weight KG
24.1
21.3
46.7%
0.468
Current Min
Max
Level
2
1
2
Cycle On
30
30
30
Cycle Off
98
134
66
Total Air M3/h
M3/h
8347
6552 11232
Air/WGT
M3h/kg 0.9
0.7
1.20