Program A (for Heaters)
•
Diff below Target to Operate: Set the degree of difference below the target temperature for
stir fans to operate.
•
Cycle On time (sec): Define the length of time in seconds you would like the stir fan to operate
during the cycle.
•
Cycle Off time (sec): Define the length of time in seconds you would like the stir fan to be off
during the cycle.
•
From/To Level: Limit the program to operate between the levels defined.
•
From/To Time: Define the time frame for the program to operate (24-hour format).
•
Stop During Fan Operation: Select YES run the heaters when the fans are operating.
Program B (for Min Vent)
•
Operate after End of Cycle: Set when stir fan begins operating. It can be at the end of the
ON cycle or the OFF cycle set in the
DEVICE | Levels of Ventilation
.
•
Delay for Operation (sec) (+/-): Define length of time in seconds from the end or start of
cycle you chose in Operate after end of cycle above, for the stir fans to operate.
•
Time for Operation (sec): Define length of time in seconds for the stir fans to operate.
•
From/To Level: Limit the program to operate between the levels defined.
•
From/To Time: Define the time frame for the program to operate (24-hour format).
Program C, D, E (Sensors Diff Temp or Independent)
•
Temp Diff to Operate: Set the degree of difference between sensors for stir fans to begin
operating.
NOTE:
If this parameter is set to 0 (zero), the variable stir fan runs independently of the sensors.
•
Diff between Sensor Number: Select a sensor to define one temperature reading.
•
Diff between Sensor Number: Select a second sensor to define a temperature reading from a
different area.
•
Cycle On time (sec): Define the length of time in seconds you would like the stir fan to operate
during the cycle.
•
Cycle Off time (sec): Define the length of time in seconds you would like the stir fan to be off
during the cycle.
•
From/To Level: Limit the program to operate between the levels defined.
•
From/To Time: Define the time frame for the program to operate (24-hour format).
•
Stop During Fan Operation: Select YES run the heaters when the fans are operating.
•
Variable Stir Fan: Select the stir fan to be used
•
Min/Max Variable Stir Fan Speed: Enter the minimum and maximum speed (in percentage).