© Munters AB, 2015
49
•
Diff between Foggers Stage = 3
Stage 1 starts at 83
°
, Stage 2 at 86
°
, Stage 3 at 89
°
, and Stage 4 at 92
°
.
4.8
Light
This menu sets the lights operating conditions. The controller has a capacity for up to four channels of
On/Off Lights
and up to 10 channels of
Dimmer Lights
. In addition, this menu enables using a light
sensor.
1. In
Install > Analog Output
(refer to Analog Output, page 110) define up to four outputs as light
dimmers.
2. In
Device Setting > Light
, define the parameters as required.
Water & Feed (page 51) configuration defines the Light Menu configuration:
•
If you select Daily, the above screen appears when you select Light; configure the Light menu
once.
•
If you select 2 – 6 Days or Week, the screen below appears.
1. Select Feed and press Enter. The Light parameters screen appears. These parameters configure
the Light functions on feed days.
2. Configure the parameters.
3. Select No Feed and press Enter. The Light parameters screen appears. These parameters
configure the Light functions on non-feed days.
4. Configure the parameters.
•
Day: Set Growth Day
In the example, the brood lights (channel 1) and bright center lights (channel 2) turn on from day
1, while the grow end lights (channel 3) are off. The example shows two channels of light dimmer,
Channel 1 at 100% and Channel 2 at 0% (for baby chicks in the brood zone).
LIGHT
Day Time
Light
Intensity (%)
1 2 3
1
2
1
12
12
12
12
25
25
25
25
0
00:00
00:00
01:00
03:00
21:00
00:00
03:00
20:00
23:00
00:00
100
45
0
45
0
0
35
0
35
0
0
45
0
45
0
0
35
0
35
0
Please Select
Light Table for Feed/No Feed
Days.
Select Table
FEED
NO FEED