![Munters Farm P-XL Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/munters/farm-p-xl/farm-p-xl_user-manual_1856887069.webp)
© Munters AB, 2015
69
•
New Group/Flock: Use the new flock function on arrival of a new set of birds to set the
growth day back to 1, 0, -1, or -2, and to clear out old history data.
5.5
Alarm Setting
This menu defines the various alarm settings.
NOTE:
See
•
Global Alarm Delay (sec): Alarms without a separate alarm delay, use this global delay
before signaling the alarm.
•
Alarm Reminder (min., 0-Disable): Amount of time before a reminder is sent if the situation
has not yet been corrected.
Sensor Alarm
•
Sensor Low Temperature Range: Sets the minimum reading a sensor can have to be
considered a valid sensor reading. Sensor readings below this are rejected. This generates a
sensor out of range alarm. This does not apply to the special Circuit Breaker Sensor or Outside
Temperature Sensor.
•
Sensor High Temperature Range: Sets the maximum reading a sensor may have to be
considered a valid sensor reading. Sensor readings above this reading are rejected. This
generates a sensor out of range alarm. This does not apply to the special Circuit Breaker
Sensor or Outside Temperature Sensor.
•
Sensor Alarm-Differential from Low Alarm: Individual sensor (or zone) alarm if any active
sensor reads this much or more below the
Control > Temperature Curve >Low Alarm
Temperature
(page 15).
•
Sensor Alarm-Differential from High Alarm: Individual active growth area sensors alarm if
they read this much or more above the
Control > Temperature Curve >Low Alarm Temperature
(page 15).
Alarms
•
Alarm Test at Time: Schedule the alarm test time.
•
Day of Alarm Test: Choose Daily or a particular day of the week for the scheduled alarm.
•
Alarm Test Duration (sec): Choose the alarm test duration.
ALARM SETTING
Global Alarm Delay (sec)
Alarm Reminder (min., 0-Disable)
SENSOR ALARM
Sensor Low Temp. Range
Sensor High Temp. Range
Sensor Alarm-Diff From Lo. Alarm
Sensor Alarm-Diff From Hi. Alarm
ALARM
Alarm Test At Time: (hh:mm)
Day Of Alarm Test:
Alarm Test Duration (sec)
AUGER OVERTIME ALARM
Auger Overtime Delay (minute)
1
30
32.0
122.0
1.0
1.0
12:00
DAILY
0
15