NOTE:
This information enables the calculation of the Wind Chill factor displayed in Hot Screen Key =
2 (Tunnel mode ONLY).
10.10
Communication
This screen defines the communication parameters.
1. Define the communication setup:
o
Baud rate: This parameter is a measure of the communication speed for local or remote
communications to a PC. The default is 9600 represents a data rate of approximately
1000 characters per second. If the connection fails at this speed, try a lower speed.
o
House number: Each controller on a network must have a unique number so Munters
communication software can distinguish individual controllers. Note that these numbers
are from 1 to 64
.
2. Define the Light Dimmer channels. Use this screen to map Farm Light dimmer units to a
communication card channel.
Farm Light Dimmers are connected to a Farm Premium Controller via a:
o
communication card or
o
analog output card
In the event that:
o
there is no analog output card installed or
o
there is a an analog output card but all outputs are defined for other devices
this screen maps the Farm Light Dimmers connected via a communication card.
NOTE:
If the Farm Premium Controller has an analog output card, you can map multiple RLD units
using an output card and a communication card. However, the Farm Premium software
prevents users from mapping a
particular
FLD unit using both methods. For example, if in
Installation > Analog Output
, you define one output as a light dimmer, Farm Premium does not
allow mapping a channel to that light dimmer.
A light dimmer and Farm Premium Extension unit can not share the same communication
card interface. Connect the communication card to one hardware type only.
COMMUNICATION SETUP
Baud Rate
9600
House Number 1
LIGHT DIMMER
Channel — a
Light Dimmer 3
Channel — b
Light Dimmer 1
Channel — c
Light Dimmer 2
Channel — d
<None>