To calibrate the ammonia level, obtain a suitable test kit and use the procedures described in the kit.
Ensure that the house is well ventilated, either naturally or using fans.
Only calibrate the sensor if you have reason to believe that they are producing inaccurate
results.
•
Define the following:
o
Ppm at 0 VDC: Parts per million at 0 VDC
o
Ppm at 5 VDC: Parts per million at 5 VDC
o
Factor (ppm): (-/+) ppm shift from the current reading
o
Ammonia (ppm): Current ammonia reading
o
Adjust the Farm Premium reading as needed using the left/right arrow keys.
o
Refer to Ammonia Treatment.
AMMONIA CALIBRATION
PPM at 0VDC
0
PPM at 5VDC
100
Factor (ppm)
0
AMMONIA (ppm) 15