12.2
Layers Vent and Curtain Levels
Set the curtain levels to correspond with the ventilation levels.
1. In
Install > Relay Outlet
(page 107), define at least one relay as a Curtain Open, Tunnel Open,
Vent Open, or Inlet Open.
2. In
Control > Temperature curve
, define the Target Temperature.
3. In
Install > Setup
, enable Natural Ventilation (page 106).
4. In
Device Setting > Vent & Curtain Levels
, define the fans' working percentages.
5. Set the Help Set parameters as required.
•
Ventilation Level: Read-only.
•
Tunnel/Curtain/Vent: Set position for the tunnel curtain by level. If you have Static Pressure in
Tunnel turned on (
Control | Static Pressure | Help | Set
), this becomes the minimum position for
the tunnel inlet.
NOTE:
Refer to Vent & Curtain Levels Help | Set Definitions for Help Set details.
12.2.1
L
AYER
I
NLET
C
ONTROL
Inlets can be controlled via two methods:
•
Pressure: In this mode, inlets open and close according to the static pressure.
•
Position: In this mode, inlets open and close according to the temperature.
To select the inlet control method:
1. Go to
Device > Vent & Curtain Levels > Help
.
2. Scroll down to Zone Inlet and select Press or Pos.
DEVICE SETTING
1. LEVELS OF VENTILATION
2. SPEED FAN LEVELS
3. VENT & CURTAIN LEVELS
4. STIR FAN LEVELS
5. STIR FAN PROGRAM
6. COOL PAD
7. FOGGERS
8. LIGHT
9. WATER & FEED
10. EXTRA SYSTEMS
11. EMERGENCY SETTING
12. WATER ON DEMAND
13. NATURAL PROGRAM
VENT & CURTAIN LEVELS
Level Attic
Tunnel
1
2
3
4
5
6
7
8
9
10
45
45
40
40
45
45
45
45
45
40
45
45
40
40
45
45
45
45
45
40