98
9.6
Feed Calibration
Farm Premium can use silo scales or less expensive digital monitoring devices to keep track of your feed.
This menu calibrates the digital monitoring devices.
1. Select the feed counting method. Your digital monitoring device may generate a dry contact
pulse for each quantity of feed, or it may simply indicate that the feed is running.
2. Enter the quantity of feed per pulse in case you use a dry contact pulse. Otherwise, enter the
amount of feed delivered per minute of auger operation.
3. Select one of the following:
o
Pulse: Weight per pulse
o
Time: Weight per minute
o
Current Sense: Motor run time when the auger contains feed
4. Enter quantity (weight per minute or per pulse).
9.7
Water Calibration
Farm Premium supports up to four dry contact pulse output water meters. Enter the quantity of water per
pulse for your water meters.
9.8
Ventilation Potentiometer Calibration
Use this screen to calibrate the ventilation potentiometer control. Potentiometer calibration is required
before ventilation can be controlled via a potentiometer.
Before calibrating the potentiometers:
o
Disable the static pressure unit in Install > Setup (page 106).
o
Define at least one relay as vent/inlet/tunnel in Install > Relay Outlet (page 107).
FEED CALIBRATION
Feed
1
2
3
4
Method
Factor
TIME
2.203
TIME
2.203
TIME
2.203
TIME
2.203
Method Pulse: Weight per Pulse
Method Time: Weight per Minute
Method Current: Weight per Minute
WATER CALIBRATION
Water 1
–
Water Per Pulse
Time
Water 2
–
Water Per Pulse
Time
Cool Pad –
Water Per Pulse
2.203
Fogger
–
Water Per Pulse
2.203
POTENTIOMETER CALIBRATION
Pot
Device Close Current Open
1
Vent 1 152
0
1000
2
Vent 2 152
0
1000