Not Empty Time [minutes]: This parameter sets an alarm for the feed scale container.
The container should distribute all of its feed to the feed lines. If feed remains in the
container, it could mean that there is a problem (for example, the valve doesn't open).
Set the amount of time that feed can remain in the container, after which an alarm
appears on the Main Screen.
o
Stop Differential 1/2/3/4 Weight: After each silo stops supplying feed to its auger
line, a certain amount of feed continues to flow. This differential compensates for this
excess and ensures that only the required amount gets to the feed container. Enter the
approximate amount of feed that can be found in the augers. The number does not need
to be exact. In the following feed runs, Farm Premium will correct the amount entered.
o
Optimizer: This parameter sets the unit's sensitivity to signal noise (caused by a variety of
factors). The sensitivity plays a role as the controller stabilizes itself. Greater amounts of
noise require faster optimization. To view an indication of the controller's stability, go to
Scale Menu > Test
(refer to page 61) and perform a test. If the number remains stable,
slower optimization is indicated. There are three settings; Default, Slower, Faster.
NOTE:
Munters recommends leaving this parameter at the default level.
o
Valve Close Time [seconds]: Set the delay in time, if any, that the valve emptying the
feed scale closes.
o
Feed Tare [A/D count]: This specification is used for certain tests performed by a
certified technician.
NOTE:
Munters recommends leaving this parameter unedited.
4.14.2
F
EED
S
CALE
H
OT
S
CREEN
Press "Right and Up Arrows" to view the Feed Scale Hot Screen.
This screen shows the status of different areas of the feeding apparatus. illustrates the system components.
•
Status: Shows the feed scale status: Idle, Emptying, or Filling.
•
Weight: Shows the feed scale container weight.
•
Auger 1/2/3/4: Shows if the auger is running (√) or closed (●)
•
Valve: Shows if the valve emptying the feed scale is open.
•
Feed S. Active: This field shows which controller is managing the feed scale.
•
Feed S. Interlock: The Feed Scale Interlock is a digital sensor which detects which damper is
active.
•
Hopper: The hopper is a digital sensor which detects if the feed has reached the maximum
level in the feed bin. Define this sensor in Install > Digital Sensor. This screen shows the sensor's
current status. If the feed reaches the maximum amount, an alarm is triggered.
FEED SCALE STATUS
Status
Idle
Weight
1000
Auger 1
√
Auger 2
√
Auger 3
●
Valve
√
Feed S. Active
Feed S. Interlock
Hopper
Open
Intermediate
Open
Alarm
0N