![MPE XR III series Скачать руководство пользователя страница 127](http://html1.mh-extra.com/html/mpe/xr-iii-series/xr-iii-series_operators-manual_1843049127.webp)
d.
Stop Bits to 1.
e.
Flow control to None.
5.
Click the OK button.
6.
On the menu bar, select File, Properties to open the Properties dialog box.
7.
Click on the Settings tab, and click the ASCII Setup button.
8.
On the ASCII Setup dialog box, set the following:
a.
Send line ends with line feeds.
b.
Echo typed characters locally.
c.
Append line feeds to incoming line ends.
9.
Press the OK button to close the ASCII Setup dialog box.
10.
Press the OK button to close the Properties dialog box.
D.3
485DSS Address Command
A command is required to address each individual 485DSS module. Once addressed, the
module will transparently convert serial data. The address command can only be
transmitted at 9600 baud, and if the command is transmitted at any other baud rate, the
command will be ignored by the 485DSS module. The address command has the following
form: Xoff character, the most significant address character, the least significant address
character, and SOH character. Xoff and SOH require a combination of keys to produce the
desired character in HyperTerminal. Simultaneously pressing the Ctrl key and the S key
(Ctrl+S) will produce the Xoff character and simultaneously pressing the Ctrl key and the
A key (Ctrl+A) will produce the SOH character. The address range of the 485DSS module
is from 0 to 255 in decimal or 0 to FF in hex. With HyperTerminal all addresses must be
entered as hex.
For an example, to set a 485DSS module with an address of 8F in hex (143 in decimal), the
address command is: Xoff 8 F SOH. To enter this data into HyperTerminal, the key
sequence is Ctrl+S, 8 key, F key and Ctrl+A. If the address is less than 10 hex, a leading
zero is required.
D.4
485DSS Communications using HyperTerminal
This section covers RS485 communications to the power supply using the HyperTerminal
and the 485DSS.
1.
Configure the power supply for remote operation.
2.
Set the address of the 485DSS module using the procedure in the previous section.
The SEL LED should light.
3.
On the menu bar in HyperTerminal, press Call, Disconnect.
4.
On the menu bar in HyperTerminal, press File, Properties to open the Properties
dialog box.
5.
In the Properties dialog box, press the Configure button to open the COM
Properties dialog box. Change the Bits per second to 19200 and then press the OK
button.
6.
Click the OK button on the Properties dialog box.
115
Содержание XR III series
Страница 1: ...OPERATING AND SERVICE MANUAL XR SERIES III DC POWER SUPPLIES...
Страница 2: ......
Страница 3: ...MAGNA POWER ELECTRONICS INC 39 ROYAL ROAD FLEMINGTON NJ 08822 February 20 2012...
Страница 4: ......
Страница 88: ...Figure 4 1 Status Byte Generation Figure 4 2 ESE and ESR Generation 76...
Страница 95: ...IEEE Standard CLS ESR ESE STB SRE IDN SAV RCL RST Notes 1 C command Q query 83...
Страница 97: ...Figure 5 1 Configuration setup Figure 5 2 GPIB communications setup 85...
Страница 99: ...Figure 5 4 Virtual Control Panel Figure 5 5 Command Panel 87...
Страница 102: ...Figure 5 7 Calibration Panel Figure 5 8 Firmware Panel 90...
Страница 103: ...Figure 5 9 Modulation Panel 91...
Страница 123: ...Figure B 1 Information Panel Figure B 2 Configure Panel 111...
Страница 124: ...Figure B 3 Reboot in Progress Panel Figure B 4 Web Control Panel 112...