Operating from both sides, unscrew and remove both screws (1).
•
Remove the oil sump guard.
•
Place a container with +4,000 cm³ (244
cu in) capacity under the drainage plug
(3).
•
Unscrew and remove the drainage
plug (3).
•
Pull out the oil filler plug / engine oil
level dipstick (4).
•
Drain the oil into the container; allow
several minutes for oil to drain out com-
pletely.
•
Insert the oil filler plug / engine oil level
dipstick (4).
•
Check and if necessary, replace the
drainage plug (3) sealing washers.
•
Remove any metal deposits attached
to the drainage plug (3) magnet.
•
Screw and tighten the drainage plug
(3).
DO NOT DISPOSE OF OIL INTO THE ENVIRONMENT.
DISPOSE OF ENGINE OIL IN A SEALED CONTAINER AND
TAKE IT TO YOUR SUPPLIER OR TO THE NEAREST USED
OIL COLLECTION CENTRE.
Stelvio 1200 NTX MY11
Maintenance
MAIN - 65
Содержание Stelvio 1200 MY11 2011
Страница 1: ...SERVICE STATION MANUAL B043090 Stelvio 1200 NTX MY11 ...
Страница 4: ......
Страница 6: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Страница 54: ...INDEX OF TOPICS SPECIAL TOOLS S TOOLS ...
Страница 61: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Страница 72: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Страница 133: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Страница 146: ...INDEX OF TOPICS ENGINE ENG ...
Страница 147: ...Gearbox Diagram key 1 Ball bearing Stelvio 1200 NTX MY11 Engine ENG 147 ...
Страница 255: ...INDEX OF TOPICS POWER SUPPLY P SUPP ...
Страница 267: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Страница 295: ...INDEX OF TOPICS CHASSIS CHAS ...
Страница 326: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Страница 356: ...INDEX OF TOPICS BODYWORK BODYW ...
Страница 378: ...INDEX OF TOPICS PRE DELIVERY PRE DE ...