2.8.1 Front
Panel
Eleven buttons and a digitizing knob are provided for normal control
and setup of the generator.
Display
The display is a Liquid Crystal Display that can display two rows of 20
characters. Items that are shown on the display are grouped into two
main categories. The top line of the display is used to show the output
of the GMW-25 RF Generator regardless of the controlling source (i.e.
front panel or ENI monitor). The AUX LEV, FWD, and REV fields
cannot be changed by the user. These fields will change, however,
depending upon the status of the generator. The AUX LEV will show
the auxiliary level (i.e. load power leveling). The FWD field shows the
amount of power in watts that is applied as forward power. The REV
field shows the amount of power in watts that is applied as reverse
power. The MODE field is used to show the Leveling mode that is
currently in use. The possible choices for this field read FP for forward
power and LP for load power.
The second line shows the set point in watts and the frequency
presently selected by the generator. The frequency can be changed by
the user if the configuration of the generator allows the frequency to be
changed; otherwise, the generator is configured as a fixed-frequency
generator, in which case the status portion of the display will indicate
“NORMAL” rather than a frequency.
000000W00 00000 0000
000000W0000000000000
STATUS
SETPOINT
REV
FWD
MODE
AUX LEV
AUX LEVEL:
Leveled feedback.
Displays 0 - 99999W for watts.
MODE:
Displays one of two choices:
FP - forward power leveling
LP - load power leveling
FORWARD:
Displays forward power in
watts. Displays 0 - 99999.
REVERSE:
Displays reverse power in
watts. Displays 0 - 9999.
SETPOINT:
User set point.
Displays 0 - 99999W for watts.
STATUS:
Any text message up to 13 characters. It displays
frequency in frequency tune mode, System Fault
messages and Interlock Open messages.
3W FP 3 1
46W 2000000 Hz
RE V
FWD
SET POI NT
STATUS
AUX LEV
MODE
Example of display