Operation
3-8
GMW-25
3.1.3
Matching Network Configuration for Generator Control
Operating the Matching Network through the ENI Monitor is possible
with the entire line of GMW-25 generators.
Setting the MATCHWORK
®
up for Generator control
Control of the MW is possible through the generator upon setting the
MATCHWORK into generator control mode. To do this, you must
establish communications with MATCHWORK and perform the
following steps.
KEY1234
e
1. To enter the CAL menu, the Level B commands must be accessed.
Type KEY1234 and press ENTER.
CAL
2. At the command prompt, type the command CAL.
Note:
Do not type CAL9 directly; you will not be able to save any of
the changes.
The matching network will attempt to communicate with the
generator immediately, even though there is no connection
between the two, and a flurry of information will appear across the
screen disabling any further communications.
3. A menu of numbered options appears.
*CAL
MATCH WORK SETUP PROCEDURE 6-13-96
[ MATCHWORK CALIBRATION MENU ]
[ Press :
1 - For Cal Starting point
3 - For Matchwork DC Bias Cal
4 - For Matchwork Vp-p Cal
5 - For Matchwork V protect Cal
6 - For Matchwork Sensors Cal
7 - For Matchwork Low Power Cal
8 - For C1 and C2 Capacitor Position Cal
9 - For Switch Selection
E - To View Calibration Settings
F - To Save Calibration Permanently & Exit
{ENTER} - to EXIT now ]
9
e
4. Select and enter number 9 - Switch selections.
[ SWITCH SELECTION ]
[ Press :
1 - To Toggle Control Type, Host/Front/Gen/Aux
2 - To Roll Matchwork Type, MW10LD/MW20LD/40MHz
{ENTER} - to EXIT now ]
1
e
5. Select option 1, the Gen control option, following the menu
directions and then press ENTER.