Appendix A
A-2
GMW-25
GMW-25 Specifications
RF Output Frequency
1.80
-
2.17
MHz
(auto-tunes within this range to
optimize match with load impedance)
RF Output Power
Rating into Matched Load
2500
W into a 50
Ω
load
RF Output Power
Rating into Mismatched Load
(All Phases)
Dynamic Power Range
25
-
2500
W
Load Impedance Range
Unlimited
RF Stability /
Spurious Output
Unconditionally stable / < -50
dBc
(for any load, within ratings)
Harmonic Output /
Distortion
< -40
dBc
(within ratings)
Power Control /
Regulation
AC Line-to-Power: 0.5% max. change
in output power over rated line
voltage range.
Regulation tolerance is referenced
from Set Point. Subject to limits of
Forward & Reverse Power and
Current; accuracy relative to ENI
Power Standard.
Power Range
Reg. Tolerance
>250W
+1%
<250W
+2.5W
Load Mismatch Protection
Automatic; forward power limits
typically 0.25 ms after reverse power
reaches a pre-programmed level 20%
of rated power.
Primary AC Power Source
3/PE
~, 200
-
208
V
±
10%,
15
A, 50
-
60
Hz
±
3
Hz
Power Consumption
5.4
kVA
Load Power
Load VSWR
2500
W 1.5:1
2000
W 2.0:1
1500
W 3.0:1
500
W
∞
:1