System
Installation
GMW-25
2-9
Pin Name
Type
Description
8
REMOTE
CONTROL
SELECT
DI
Connect to Pin 31 to enable analog remote
control. Leave disconnected to disable analog
remote control.
Note:
If the generator is in digital remote mode
(via 9-pin port for RS-232), it cannot
switch to analog remote mode until the
digital remote mode is disabled.
Therefore, setting this pin low will have
no effect until the digital remote mode is
disabled.
9
GENERATOR
FAULT (E)
DO
Emitter side of isolated transistor switch. (See
Note 1)
Transistor ON - Generator fault
Transistor OFF - No fault
Signal Definition:
Generator Fault = generator overheat condition
or interlock broken.
10
INTERLOCK
This pin should connect to Pin 35 to complete
the interlock chain.
If the interlock chain is broken, the AC contactor
will open.
External circuit should be capable of switching
100 mA at 24 VAC.
11
15 VDC
RETURN
Isolated 15-volt return from customer system.
12-25
No Connect
N/A
NONE
26
MAX POWER
(C)
DO
Collector side of isolated transistor switch for
Pin 1.
27
REFLECTED
POWER RTN (-)
AO
Signal return for Pin 2.
28
FORWARD
POWER RTN (-)
AO
Signal return for Pin 3.
29
RF ON/OFF
CONTROL
DI
Connect to Pin 4 to turn RF ON.
Leaving this pin open will turn RF OFF.
30
POWER
SETPOINT
RTN (-)
AI
Signal return for Pin 5.
31
REMOTE
CONTROL
SELECT
DI
Signal return for Pin 8.
DI = Digital Input
DO = Digital
Output
AI = Analog
Input
AO = Analog Output
37-pin Analog I/O Interface (Cont’d)
Table 2.4.2