Troubleshooting
GMW-25
4-3
4.2 System
Faults
A fault that occurs within the unit will show up as the following on the
front panel display:
3 FP 0 1
46W SYSTEM FAULT
REV
FWD
SET POINT
STATUS
AUX LEV
MODE
These faults can only be diagnosed using an external control device
such as the ENI Monitor. When the system fault occurs, a SYSTEM
FAULT LED will illuminate on the front panel. Use the
RFV
and the
RPS
command (see section 3.2.3) on the ENI monitor to determine the
fault. Using the equal sign (=) after the
RFV
command will show the
fault in words instead of a numerical value.
This way of diagnosing a fault is only available if the unit has a fully
functional front panel and the Analog Remote Interface is connected to
a terminal to use the ENI Monitor.
Otherwise, if and when a system fault occurs, only the SYSTEM
FAULT LED will illuminate.
Interlock status is shown on the front panel if the unit is open.
“
INLK OPEN
” will be displayed on the STATUS line.