Operation
GMW-25
3-7
Changing the requested power
Once the ENI monitor has established control of the generator, the
requested power can be entered.
OEM
XXXX
e
1. Type the command
OEM XXXX
from the ENI Monitor keyboard and
press Enter. You can enter in place of XXXX any value from 0 to
2500. This is the number of watts you want the generator to be set
to produce. The value you entered should appear on the Front
Panel display under the SET POINT field.
RSE <->
e
2. Type the command
RSE
to return the set point to the ENI monitor.
The escape key can be used to escape the continuous real-time
monitoring.
To request RF power, do the following:
TRG
e
1. Type the command
TRG
from the ENI Monitor keyboard and press
Enter. The RF ON LED will illuminate (located to the right of the
Digitizer Knob and to the left of the circuit breaker). To turn off the
RF power, you would type
OFF
from the ENI Monitor keyboard.