Operation
3-14
GMW-25
3.2.2 Generator
Control
The generator control commands allow the user to control some of the
operation of the generator from the external monitor.
Command Option
Description
FRE
All internal faults will be reset. Take note, however, that if a fault
persists, it will only be cleared for a fraction of a second until it is
detected again and set. In this case, the fact that the fault was
actually cleared will not be observable to the user.
FTU
< n >
n = 1, The generators frequency tuning feature is turned on.
n = 0, The generator’s frequency tuning feature is turned off.
KEY
< key >
Depending on the value of key, different access levels into the
generators software will be granted. These higher access levels (B
and C) allow different digital commands to be accessible to the user
(i.e. calibrations, direct memory access, etc.).
LIT
This will disable link integrity checking. The link integrity feature is
turned on automatically when a ^w (Control W) is received over the
serial link.
LLT
< n >
n = 0, Forward power leveling is enabled.
n = 1, Load power leveling is enabled
OEM
< power >
The result will be to set the generator’s output power set point to the
value specified as power. In the event that power is greater than the
maximum allowable set point, the set point will be equal to the
maximum power output set point.
TRG
If RF is currently off in the generator, it will be switched on. If RF is
already on, this command has no effect.
OFF
If RF is currently on in the generator, it will be switched off. If RF is
already off, this command has no effect.
SBD
< n >
This command will change the baud rate at which the generator is
currently communicating.
n BAUDRATE
0. 300
1. 600
2. 1200
3. 2400
4. 4800
5. 9600
6. 19200
7. 38400
8. 76800
9. 115200
Generator Control Commands
Table 3.2.2
Note:
These commands are available in Version 1.1 software and any versions that follow
it.