Operation
3-22
GMW-25
Setting the Minimum Search Threshold
Minimum Search Threshold
This software parameter refers to a pre-defined value that
prevents the Auto-Tune algorithm from searching for a frequency
when the reflected power is below the pre-defined limit.
ITEM
1. Press the Item Up button to change the display to the next menu
item. The display should look like this:
FREQUENCY MENU
Threshold-> 10W
RE V
FWD
SET POI NT
STATUS
AUX LEV
MODE
2. Use the digitizer knob to select a minimum search threshold. The
range is from 0.0 W to 1.0 W.
Setting the delay time
ITEM
1. Press the ITEM UP button to change the display to the next menu
item. The display should look like this:
FREQUENCY MENU
Delay-> 670ms
RE V
FWD
SET POI NT
STATUS
AUX LEV
MODE
2. The delay time sets the time for which the algorithm remains at the
start frequency. The delay should be chosen to ensure that ignition
is achieved reliably and the plasma is stable before the frequency
starts to move. Use the Digitizer Knob to select a delay time from
100 ms to 8000 ms.
Содержание GMW-25
Страница 4: ...This page intentionally left blank...
Страница 43: ...System Installation GMW 25 2 21 Safety Interlock Locations Rear View Figure 2 7...
Страница 96: ...Appendix B B 2 GMW 25 This page intentionally left blank...
Страница 98: ...Appendix C C 2 GMW 25 This page intentionally left blank...