(d) Canceling ON/OFF registration data
The registered forced ON/OFF data can be canceled using GX Developer.
Once the registered data is canceled, the status of the forced ON/OFF registered
devices will be as follows.
Forced ON/OFF setting can be cleared by any of the following operations.
• Power supply OFF ON
• Reset operation using the RESET/L.CLR switch or RUN/STOP/RESET
switch of the CPU module
• Reset with remote reset operations
Note16
Table6.19 Status of devices after forced ON/OFF registration data is canceled
Forced ON/OFF registered device
ON/OFF performed with
sequence programs
ON/OFF not performed with
sequence programs
Input
Input from modules mounted
on the base unit
Assumes the ON/OFF status received from the module.
Input of CPU module to be
refreshed from LX of
CC-Link IE controller network
or MELSECNET/H
Assumes the refreshed ON/OFF status from CC-Link IE
controller network or MELSECNET/H.
Input of CPU module to be
refreshed from RX of CC-Link
Assumes the refreshed ON/OFF status from CC-Link.
Input other than above
(outside of the refresh range)
Operation result in the
sequence program is
reflected.
Maintains the enforced ON/
OFF status.
Output
Output from modules mounted
on the base unit
Outputs the results of the
sequence program operations.
Retains the registered ON/
OFF status.
Output of CPU module to be
refreshed from LX of
CC-Link IE controller network
or MELSECNET/H
Outputs the results of the
sequence program operations.
Retains the registered ON/
OFF status.
Output of CPU module to be
refreshed from RX of CC-Link
Outputs the results of the
sequence program operations.
Retains the registered ON/
OFF status.
Output other than above
(outside of the refresh range)
Assumes the result of the
sequence program operations.
Maintains the enforced ON/
OFF status.
Basic
Note6.15
The Basic model QCPU does not support the forced ON/OFF registration operation from the
Forced input output registration/cancellation screen (
The Basic model QCPU can forcibly turns ON/OFF external I/O only by executing a device test in
GX Developer.