App
- 21
Appendix 1 Special Relay List
APPENDICES
ACPU
Special
Relay
Special
Relay after
Conversion
Special
Relay for
Modification
Name
Meaning
Details
Corresponding
CPU
M9103
SM1103
SM323
Presence/absence
of continuous
transition
OFF : Continuous transition
not effective
ON : Continuous transition
effective
• Set whether continuous transition will be performed for the
block where the "continuous transition bit" of the SFC
information device is not set.
QnA
Qn(H)
QnPH
M9104
SM1104
SM324
Continuous
transition
suspension flag
OFF : When transition is
completed
ON : When no transition
• OFF during operation in the continuous transition mode or
during continuous transition, and ON when continuous
transition is not executed.
• Always ON during operation in the no continuous
transition mode.
M9108
SM1108
SM90
Step transition
monitoring timer
start (equivalent of
SD90)
OFF : Monitoring timer reset
ON : Monitoring timer reset
start
• Turns ON when the measurement of the step transition
monitoring timer is started.
Turning this relay OFF resets the step transition
monitoring timer.
M9109
SM1109
SM91
Step transition
monitoring timer
start (equivalent of
SD91)
M9110
SM1110
SM92
Step transition
monitoring timer
start (equivalent of
SD92)
M9111
SM1111
SM93
Step transition
monitoring timer
start (equivalent of
SD93)
M9112
SM1112
SM94
Step transition
monitoring timer
start (equivalent of
SD94)
M9113
SM1113
SM95
Step transition
monitoring timer
start (equivalent of
SD95)
M9114
SM1114
SM96
Step transition
monitoring timer
start (equivalent of
SD96)
M9180
SM1180
SM825
Active step
sampling trace
completion flag
OFF : Trace started
ON : Trace completed
• Set when sampling trace of all specified blocks is
completed. Reset when sampling trace is started.
QnA
M9181
SM1181
SM822
Active step
sampling trace
execution flag
OFF : Trace not being
executed
ON : Trace execution under
way
• Set when sampling trace is being executed.Reset when
sampling trace is completed or suspended
M9182
SM1182
SM821
Active step
sampling trace
permission
OFF : Trace disable/suspend
ON : Trace enable
• Selects sampling trace execution enable/disable.
ON
: Sampling trace execution is enabled.
OFF : Sampling trace execution is disabled. If turned off
during sampling trace execution, trace is
suspended.
M9196
SM1196
SM325
Operation output
at block stop
OFF : Coil output OFF
ON : Coil output ON
• Selects the operation output when block stop is executed.
ON
: Retains the ON/OFF status of the coil being used
by using operation output of the step being
executed at block stop.
OFF : All coil outputs are turned off. (Operation output
by the SET instruction is retained regardless of
the ON/OFF status of M9196.)
QnA
Qn(H)
QnPH
M9197
SM1197
Switch between
blown fuse and I/O
verify error display
SM
1197
SM
1198
I/O numbers
to be
displayed
Switches I/O numbers in the fuse blow module storage
registers (SD1100 to SD1107) and I/O module verify error
storage registers (SD1116 to SD1123) according to the
combination of ON/OFF of the SM1197 and SM1198.
OFF
OFF
X/Y0 to 7F0
ON
OFF
X/Y800 to
FF0
M9198
SM1198
OFF
ON
X/Y1000 to
17F0
ON
ON
X/Y1800 to
1FF0
M9199
SM1199
Data recovery of
online sampling
trace/status latch
OFF : Data recovery disabled
ON : Data recovery enabled
• Recovers the setting data stored in the CPU module at
restart when sampling trace/status latch is executed.
• SM1199 should be ON to execute again. (Unnecessary
when writing the data again from peripheral devices.)