4.4 Base Unit Assignment (Base Mode)
4
I/O NUMBER ASSIGNMENT
(3) Setting screen and setting items for Base mode of GX Developer
(a) Base model name
Set the mounted base unit model name within 16 characters.
CPU module does not use the designated model name. (It is used as a user's
memo or for parameter printing)
(b) Power model name
Set the mounted power supply module model name within 16 characters.
CPU module does not use the designated model name. (It is used as a user's
memo or for parameter printing)
(c) Extension cable
Set the used extension cable model name within 16 characters.
CPU module does not use the designated model name. (It is used as a user's
memo or for parameter printing)
(d) Slots (Used with CPU module)
Select the number of points for the slot of the base unit being used from the
followings:
• 2(2slots)
• 3(3slots)
• 5(5slots)
• 8(8slots)
• 10(10slots)
• 12(12slots)
(e) 8slot Default/12slot Default (Used with CPU module)
Select either option to designate the number of slots for all base units to the same
number.
(f) Auto/Detail
Select whether base unit assignment will be made in Auto mode or Detail mode.
Figure 4.15 I/O assignment
(a)
(b)
(c)
(d)
(e)
(f)