6
- 184
6.24 Serial Communication Function
6
FUNCTIONS
(5) Setting of transmission specifications
Use the serial communication setting PLC parameters to set the transmission speed,
sum check, transmission wait time and online change setting of the serial
communication function.
• When using the serial communication function to make communication with the
personal computer, Display device or the like, specify "Use serial
communication".
• Set the transmission speed, sum check, transmission wait time and RUN write
setting.
(6) Instructions
(a) When switching the connection target to GX Developer during
communication with display device or like
Connection can be switched to GX Developer during communication with the
personal computer, Display device or the like using the serial communication
function.
However, the personal computer, Display device or the like that was making
communication using the serial communication function results in a
communication error.
Refer to the manual of the used device for the way to start the personal computer,
Display device or the like when the CPU module is reconnected with the personal
computer, Display device or the like.
(b) Transmission speed set on Connection setup screen
When "Use serial communication" is selected, the transmission speed set on the
Connection setup screen of GX Developer is ignored.
POINT
The data set in serial communication setting is made valid when:
• The PLC is powered on; or
• The CPU module is reset.
Figure 6.108 Serial communication setting screen
Click here to use the serial
communication function.
Selecting "Use serial
communication" allows you to
change the setting.