APPENDICES
Appendix 1 Special Relay List
App
- 20
9
P
a
ra
met
e
rs
10
Device
Exp
la
n
at
ion
11
CP
U
M
odu
le
P
ro
cessi
ng
Ti
m
e
12
P
roc
e
d
ure
f
or W
rit
in
g
P
rog
ra
m t
o CP
U Mo
du
le
A
p
pe
nd
ic
e
s
In
de
x
*1: The A8UPU/A8PUJ is not available for the QCPU/QnACPU.
ACPU
Special
Relay
Special
Relay after
Conversion
Special
Relay for
Modification
Name
Meaning
Details
Corresponding
CPU
M9056
SM1056
Main side P, I set
request
OFF : Other than when P, I
set being requested
ON : P, I set being
requested
• Provides P, I set request after transfer of the other
program (for example subprogram when main program is
being run) is complete during run. Automatically switched
off when P, I setting is complete.
QnA
Qn(H)
QnPH
M9057
SM1057
Sub side P, I set
request
OFF : Other than when P, I
set being requested
ON : P, I set being
requested
M9058
SM1058
Main side P, I set
completion
Momentarily ON at P, I set
completion
• Turned ON once when the P, I set has been completed,
and then turned OFF again.
M9059
SM1059
Sub program P, I
set completion
Momentarily ON at P, I set
completion
M9060
SM1060
Sub program 2 P, I
set request
OFF : Other than when P, I
set being requested
ON : P, I set being
requested
• Provides P, I set request after transfer of the other
program (for example subprogram when main program is
being run) is complete during run. Automatically switched
off when P, I setting is complete.
M9061
SM1061
Sub program 3 P, I
set request
OFF : Other than when P, I
set being requested
ON : P, I set being
requested
M9065
SM1065
SM711
Divided transfer
status
OFF : Divided processing not
underway
ON : During divided
processing
• Turned on when canvas screen transfer to AD57(S1)/
AD58 is done by divided processing, and turned off at
completion of divided processing
QnA
M9066
SM1066
SM712
Transfer
processing switch
OFF : Batch transfer
ON : Divided transfer
• Turned on when canvas screen transfer to AD57(S1)/
AD58 is done by divided processing.
M9070
SM1070
A8UPU/
A8PUJrequired
search time*
OFF : Read time not
shortened
ON : Read time shortened
• Turned ON to shorten the search time in the A8UPU/
A8PUJ.
(In this case, the scan time is extended by 10 %.)
QnA
Qn(H)
QnPH
M9081
SM1081
SM714
Communication
request
registration area
BUSY signal
OFF : Empty spaces in
communication
request registration
area
ON : No empty spaces in
communication
request registration
area
• Indication of communication enable/disable to remote
terminal modules connected to the AJ71PT32-S3, A2C or
A52G.
QnA
M9084
SM1084
Error check
OFF : Error check executed
ON : No error check
It is set whether the error checks below are performed or not
when the END instruction is processed (to set the END
instruction processing time).
• Check for fuse blown.
• Check of battery
• Collation check of I/O module
QnA
Qn(H)
QnPH
M9091
SM1091
Operation error
details flag
OFF : No error
ON : Error
• Turns ON when the detail factor of the operation error is
stored into SD1091.
• Remains ON if the condition is restored to normal
thereafter.
M9094
SM1094
SM251
I/O exchange flag
OFF : Exchanged
ON : Not exchanged
• The I/O module can be changed online (with power on)
when SM251 is turned ON after the head I/O number of
the I/O module is set to SD251. (One module only is
allowed to be changed by one setting.)
• To be switched on in the program or peripheral device test
mode to change the module during CPU RUN. To be
switched on in peripheral device test mode to change the
module during CPU STOP.
• RUN/STOP mode must not be changed until I/O module
change is complete.
QnA
M9100
SM1100
SM320
Presence/absence
of SFC program
OFF : SFC programs not
used
ON : SFC programs used
• Turned on if the SFC program is registered.
• Turned off if the SFC program is not registered.
QnA
Qn(H)
QnPH
M9101
SM1101
SM321
Start/stop SFC
program
OFF : SFC programs stop
ON : SFC programs start
• The value in SM320 is set as the initial value.
(The relay automatically turns ON when the SFC program
is present.)
• When this relay turns from ON to OFF, execution of the
SFC program stops.
• When this relay turns from OFF to ON, execution of the
SFC program resumes.
M9102
SM1102
SM322
SFC program start
status
OFF : Initial start
ON : Resume start
• The SFC program start mode in the SFC setting of the
PLC parameter dialog box is set as the initial value.
At initial start: OFF
At continue start: ON
Содержание Q00CPU
Страница 1: ......
Страница 2: ......
Страница 972: ...Index 6 Memo ...
Страница 975: ......
Страница 976: ......