3 - 19 3 - 19
3 SPECIFICATIONS
3.5 I/O Signal List
The following describes the I/O signal list of the L series master/local module. The "n"
in the table indicates the master/local module's first I/O number of the L series, which is
determined by both the installation position and the module installed before the L
series master/local module.
<Example> When the master/local module's first I/O number of the L series is X/Y30
Xn0 to X (n + 1) F X30 to X4F
Yn0 to Y (n + 1) F Y30 to Y4F
Signal direction:
Programmable controller CPU
L series master/local module
Signal direction:
Programmable controller CPU
L series master/local module
Availability Availability
Input number
Signal name
Master station Local station
Output number
Signal name
Master station Local station
Xn0 Module
error
Yn0
Xn1
Host data link status
Yn1
Xn2 Use
prohibited —
—
Yn2
Xn3
Other station data link status
Yn3
Xn4
Yn4
Xn5
Yn5
Xn6
Yn6
Xn7
Yn7
Xn8
Yn8
Xn9
Yn9
XnA
YnA
XnB
YnB
XnC
YnC
XnD
YnD
XnE
Use prohibited
—
—
YnE
XnF Module
ready
YnF
X (n+1) 0
Y (n+1) 0
X (n+1) 1
Y (n+1) 1
X (n+1) 2
Y (n+1) 2
X (n+1) 3
Y (n+1) 3
X (n+1) 4
Y (n+1) 4
X (n+1) 5
Y (n+1) 5
X (n+1) 6
Y (n+1) 6
X (n+1) 7
Y (n+1) 7
X (n+1) 8
Y (n+1) 8
X (n+1) 9
Y (n+1) 9
X (n+1) A
Y (n+1) A
X (n+1) B
Y (n+1) B
X (n+1) C
Y (n+1) C
X (n+1) D
Y (n+1) D
X (n+1) E
Y (n+1) E
X (n+1) F
Use prohibited
—
—
Y (n+1) F
Use prohibited
—
—
POINT
The use-prohibited output signals shown in the I/O signal list are used by the
system and cannot be used by the user.
In the event these signals are used (turned on/off) by the user, normal operations
cannot be guaranteed.
Содержание L26CPU-BT
Страница 1: ......
Страница 2: ......
Страница 7: ...A 5 A 5 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Страница 32: ...3 5 3 5 3 SPECIFICATIONS ...
Страница 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Страница 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Страница 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Страница 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Страница 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Страница 139: ...8 33 8 33 8 FUNCTIONS ...
Страница 151: ...8 45 8 45 8 FUNCTIONS ...
Страница 243: ...11 6 11 6 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS Set parameters as follows ...
Страница 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Страница 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Страница 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Страница 324: ...15 3 15 3 15 TROUBLESHOOTING 1 When the master station RUN LED is off 2 Common module check procedure ...
Страница 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Страница 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Страница 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Страница 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Страница 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Страница 439: ...App 75 App 75 APPENDIXES MEMO ...
Страница 447: ......
Страница 448: ......
Страница 449: ......